Ventilation on wall V 900-V 1400 - For installation on outside wall.
NB. Electric installations must be carried out by an authorized electrician.
Installation
The wall ventilator must be separated before installation.
(1-2)
Telescopic wall pipe (wall hole D 165/205 mm) with counter damper is installed in the
wall. NB About 3 cm wall pipe must be visible inside.
(3)
Wall ventilator should be installed outside.
(4)
Flexible hose D 160 mm is installed inside.
(5)
Lead from canopy (marked engine), mounted with extension lead, is connected to the
lead from the wall ventilator.
(6-7) Selected cabinet is installed.
Technical Data:
Type
Connection (V)
Watt expenditure
Regulation possibilities
Air quantity m
3
/h v. 0 vs.
Speed rotations
Sound level (dB)
Weight in kg
V 500
230
70
Internal
500
1400
53
4,0
V 900
230
85
Internal
900
2600
53
8,0
English
V 1400
230
78
Internal
1400
1420
62
14,0