TROUBLESHOOTING

Error
The treadmill will not start / is not func-
tional
The treadmill does not run in a straight
line or is jerky
The belt stops during training
Computer display error
E01
E02
E03
E04
E05
E07
Motor
Display fault
Display fault
No pulse display
OM2063CA Instructions manual Treadmill OMR 5.0 .indd 39
Possible cause
The mains plug is not connected to a
power socket.
Emergency stop safety key not inserted
The fuse in the treadmill interrupts the
power supply
The ON/OFF button is in the OFF position
Cable connections are interrupted
The belt has not been tensioned adequate-
ly
The belt has not been lubricated adequate-
ly
The belt has been tensioned too severely
Emergency stop safety key not inserted
The wiring for the motor has not been con-
nected properly
The connection between the circuit board
and the motor has been interrupted
No signal from the speed sensor
No self-test of tilt adjustment mechanism
Excessive current, more than 6A
The belt will not switch off. A audible warn-
ing signal is issued for approx. 9 seconds.
Computer has not received a safety signal
from the emergency stop
The emergency stop safety key is defective
The motor does not start
The display cable has not been connected
properly
Power malfunctions
Hand pulse cable interrupted
Computer cable interrupted
Remedy
Connect the mains plug to a power socket.
Insert the emergency stop safety key into
the slot.
Replace the fuse
Switch the button to ON
Check all of the cable connections
The belt must be re-adjusted
The belt must be lubricated
The belt must be loosened
Insert the emergency stop safety key into
the slot in the panel
Connect the wiring properly
Check the plug connection or replace the
circuit board
Check the plug connection between the
sensor and the circuit board or replace the
sensor
Check the cable connection to the tilt ad-
justment mechanism and the power cable.
Press the Incline key again. If the self-test
starts, you can use the device again. If the
test fails, switch the device off immediately,
and contact our Service Department.
Stop the belt and switch it off. Then restart.
Error: Excessive voltage; something is inter-
fering with the treadmill
Check if the motor is making an unusual
noise, or if you can smell burning.
Insert the emergency stop safety key into
the slot in the panel
Exchange the emergency stop safety key
Contact the service department
Check the cable connection
Set the main switch on the motor cover to
OFF. Then wait for a minute and switch the
treadmill back on.
Check the wiring
Check the wiring. Replace the computer, if
needed