doors/drawers; wait a few moments before reopening the door/drawers just
after it has been closed. During the stocking open and filling a drawer at
time to eliminate the risks of possible overbalancing of the counter.
Defrosting
Timing of defrosting (Abb.1)
The electronic control panel is pre-set to automatically execute 2 defrosting
cycles within twenty four hours. Its timer will reset to the time of the initial
first start-up. In order to modify the start time for the defrost cycle to the
desired time, it is sufficient to follow these directions, press the defrosting
key, for 3 seconds, the unit will start defrosting at that time, and another
cycle will follow 12 hours later. Automatic removal defrost system in all the
models.
7. MAINTENANCE
Periodic cleaning of cell and condenser
Before starting cleaning put the switch off and disconnect the plug. Is
important to clean the internal basin at least once a week by following the
directions see initial cleaning. Clean the condenser at least once a week.
Before starting cleaning, close and protect the unit. Access to the
condenser by loosening the locking screw of a protective grill, then remove
the dust which has deposited on the front surface of the condenser using a
broom or vacuum cleaner.
Inactivity oft he device
During periods of inactivity, put the switch off and disconnect the plug,
accurately clean the unit, as per periodic cleanings, allow air to circulate in
the cell by covering the unit with a material that allows the device to
transpire.

8. OPERATIONS IN THE CASE OF FAILURES

If the device is not functioning, make sure that:
the plug has been correctly inserted into the socket;
the supply cord is not damaged.
If the pre-set temperature is not reached make sure that:
the command switch is turned on;
the electronic control panel is correctly regulated (see setting the
cell temperature);
the device is neither in the defrosting phase nor the post-defrosting
phase;
the evaporator is not covered with frost;
the condenser is not blocked with dust;
the device is not located near heat sources or its condensing unit
is not well-aired;
the stored foods or other objects do not inhibit the proper closing of
doors/drawers;