Configuration of the limit switches for electronic motors
Use a 3 channel transmitter (or CH5..CH7 of any 7 channel transmitter) associated to the motor to be configured. Start from an intermediate point of the run.
4.1
Deprat motor
Option 1: configuration with DIP4
1
2
STOP
3
(> 2 s)
4
(> 2 s)
5
(> 2 s)
6
Move DIP5 and DIP6 to OFF.
2 s
Move DIP4 to ON. The buzzer emits a
continuous sound for 2 seconds.
2 s
Press the "STOP" button of the transmitter.
The motor makes a short movement and
the buzzer emits a continuous sound for
2 seconds.
1s
Press the "OPEN" button and hold it down
until the desired upper limit is reached.
At the button release the buzzer emits a
countinuous sound
.
5x
Press the "CLOSE" button and hold
it down until the desired lower limit is
reached. At the button release the buzzer
emits 5 fast beeps.
Move DIP4 to OFF.
Option 2: configuration with P3
1
Move DIP5 and DIP6 to OFF.
Press 8 times P3 button of a memorized transmitter,
2 s
and keep it pressed. The selected motor makes a
2
short movement and the buzzer emits a continuous
P3
sound for 2 seconds. In case of group command,
8 times
repeat this step to select another motor.
STOP
2 s
Press the "STOP" button of the transmitter. The motor
3
makes a short movement and the buzzer emits a
continuous sound for 2 seconds.
(> 2 s)
1s
Press the "OPEN" button and hold it down until the
4
desired upper limit is reached. At the button release
the buzzer emits a countinuous sound.
(> 2 s)
5x
Press the "CLOSE" button and hold it down until the
5
desired lower limit is reached. At the button release
the buzzer emits 5 fast beeps.
(> 2 s)
2x
In order to program other motors resume the
6
procedure from the step 1, otherwise exit by
pressing P3 button until the buzzer emits 2 beeps.