Herunterladen Inhalt Inhalt Diese Seite drucken

Changing The Oil; Maintenance Instructions; Ordering Spare Parts - EINHELL Royal BWP 9 Bedienungsanleitung

Benzin-wasserpumpe
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Anleitung BWP 9_SPK1
28.08.2006
GB
until the motor starts.
7. After a running time of approx. 1 minute, re-open
the choke lever (9).
8. With a warm motor, leave the choke lever in the
open position when starting. Do not actuate the
primer (5) any more once it is full.
During the priming process, the shut-off devices
present in the pressure pipe (spray nozzles,
valves etc.) must be completely open so that the
air in the suction pipe can escape freely.
The initial priming process can last for approx. 0.5
min. – 5 min, depending on the suction height and
the air quantity in the suction pipe. In the case of
longer priming periods, water should be added to
the pump housing and suction pipe again.
If the pump is disconnected again after use, then it
is imperative that the water is refilled before the
pump is connected and put into operation again.
Switching off:
Set the ON/OFF switch (6) to the "OFF" position.
Running-in period:
Since the motor has a low oil capacity (70 ml), the oil
must be changed for the first time after 1 hour of
operation. See point 10 (Changing the oil).
Misfires, start-up difficulties:
Check whether
the primer (5) is full;
the fuel filter is clean;
the throttle lever (10) is in the center position;
the air filter is clean;
the spark plug is clean and the electrode gap is
0.6 mm.

9. Maintenance instructions

Important! Pay close attention to the service
manual!
The spark plug
Dismantle the spark plug and clean away any
deposits every 50 hours of operation.
Set the electrode gap to approx. 0.6 mm.
Air filter (9)
The air filter should be removed and cleaned once
every 30 hours of operation (normal conditions) or
every 15 hours of operation (dusty conditions) (Figs.
3-4).
To do this:
1. Remove the filter cover (8).
10
12:43 Uhr
Seite 10
2. Remove the air filter (9).
3. Clean the air filter by washing it with soapy water
and drying it in the open.
4. mount the parts by following the sequence in
reverse order.
Important! Never use household cleaners or
petrol for the purposes of cleaning.
Fuel filter
The fuel filter should be dismantled and cleaned
with petrol either after approx. 30 hours of operation
or if the pump is not used for long periods.

10. Changing the oil

The motor oil is best changed when the motor is at
working temperature.
Only use motor oil (15W40).
Remove the oil dip stick (4)
Tip the device over and empty the oil through the
oil filler plug (4)
Fill with 70 ml of engine oil
Dispose of the old oil properly.

11. Ordering spare parts

Please provide the following information on all orders
for spare parts:
Model/type of machine
Article number of the machine
ID number of the machine
Number of the required spare part
For our latest prices and information please go to
www.isc-gmbh.info
We explicitly point out that, in accordance with the
German Product Liability Act, we are not liable for
any damages caused by our appliance if they result
from improper repairs to the product, if parts are
replaced by items other than our original parts or
parts approved by us, or if repairs are not carried out
by our customer services department.