Herunterladen Inhalt Inhalt Diese Seite drucken

Wasco EXDUL-581E Bedienungsanleitung Seite 72

Inhaltsverzeichnis

Werbung

Counter0
This command is used to access the counters. The counter can be started,
stopped, reset an read out. Furthermore, you can read in and reset the
overflow flag.
Code
Example as for counter0:
Counter0 Start / Stop / Reset
Byte
Transmit
0
09
1
00
2
00
3
01
bb
00
4
01
02
5
00
6
00
7
00
EXDUL-581E / EXDUL-581S © 2019 by Messcomp Datentechnik GmbH
Counter command code
00
start counter
01
stop counter
02
reset counter
03
read counter value
04
reserved
read overflow flag
05
reset overflow flag
06
Representing
Command code 1st Byte
Command code 2nd Byte
Command code 3rd Byte
Length byte
Counter command code
start counter0
stop counter0
reset counter0
reserved
reserved
reserved
wasco
Receive
Representing
09
Command code 1st Byte
00
Command code 2nd Byte
00
Command code 3rd Byte
01
Length byte
Counter command code
bb
00
reserved
00
reserved
00
reserved
®
EV03
72

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Exdul-581s

Inhaltsverzeichnis