EXDUL-336E
EDP No.: A-385340
EXDUL-336S
EDP No.: A-385320
10 optocoupler isolated digital inputs
LCD display (EXDUL-336E only)
Firmware Version 4.05
Rev. 2
8 relay outputs
2 16bit counters
wasco
user's guide
®

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Wasco EXDUL-336E

  • Seite 1 EXDUL-336E EDP No.: A-385340 EXDUL-336S EDP No.: A-385320 Firmware Version 4.05 Rev. 2 10 optocoupler isolated digital inputs 8 relay outputs 2 16bit counters LCD display (EXDUL-336E only) wasco ® user‘s guide...
  • Seite 2 EXDUL-336 and this documentation, neither for direct nor indirect damages. Important Information: This manual was written for the modules EXDUL-336E and EXDUL-336S. EXDUL-336E additionally provides an LCD display, all other functions are identical. For EXDUL-336S all commands and functions concerning the LCD display are not applicable.
  • Seite 3: Inhaltsverzeichnis

    4.2 Power Supply via USB Port .................10 4.3 Power Supply via an External Voltage Source ............10 4.4 LCD Display while Booting (EXDUL-336E only) ..........10 4.5 LCD Display while in Operation (EXDUL-336E only) ..........11 ® 5. Installing the Windows Drivers ............12 ®...
  • Seite 4 8.1 Wiring of the Inputs ....................38 8.2 Wiring of the Outputs ...................39 9. ASCII Table ..................41 10. Release Notes ................44 11. Product Liability Act ..............45 12. CE Declaration of Conformity ............47 EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 5: Description

    2 A. Two of the ten optocoupler inputs are programmable and usable as digital counters if required. EXDUL-336E additionally provides an LCD display which can display I/O status information or user specific data. Connecting to a computer is made quickly and conveniently Plug & Play via a USB interface.
  • Seite 6: Connection Terminals

    IN01+ IN02+ IN03+ IN04+ / Counter2 IN05+ IN06+ IN07+ IN09+ IN08+ IN00...09- GND_EXT Vcc_EXT Vcc_EXT: Connector for external voltage source GND_EXT: Ground connection when using external voltage source Not connected EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 7: System Components

    ® 3. System Components 3.1 Block Diagram EXDUL-336E ext. Vcc +10V...+24V Controller Counter Display EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 8: Block Diagram Exdul-336S

    ® 3.2 Block Diagram EXDUL-336S ext. Vcc +10V...+24V Controller Counter EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 9: Optocoupler Inputs

    3.6 LCD Display (EXDUL-336E only) Matrix display with 2 lines and 16 columns performing 16 characters each line Info display while booting Display of I/O status or UserLCD while in operation EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 10: Initial Start-Up

    4.1 Connection via USB Port EXDUL-336E / EXDUL-336S features a USB 2.0 interface and can be connected directly to the computer or via USB hub using the enclosed USB connecting cable. The module is hot-pluggable, this means it is con- nectable even during running operations of your computer’s system.
  • Seite 11: Lcd Display While In Operation (Exdul-336E Only)

    = Vcc via USB, c = USB connected EXDUL-336 e c e = Vcc external, c = USB connected EXDUL-336 e n e = Vcc external, n = USB not connected EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 12: Installing The Windows

    ® The Windows Device Manager will now show your USB module EXDUL- 336E / EXDUL-336S as a Wasco USB Communication Port COMx in its directory connections (COM/LTP) tree. All Windows ® software can ac- cess to the virtual interface as if it were a real COM port.
  • Seite 13: Programming On Windows

    ® 6. Programming on Windows 6.1 Overview After successful installation the USB module EXDUL-336E / EXDUL- 336S is listed as a Wasco USB Communication Port COMx in your Win- ® dows Device Manager. This is a CDC device (Communications Device Class), that is adressed via a virtual COM port.
  • Seite 14: Windows ® Functions For Programming

    ® ® 6.3 Windows Functions for Programming You can program EXDUL-336E / EXDUL-336S either via WIN32 API functions or very easily via an already existing serial port object in a pro- gramming language. You can find examples in your installation directory on your computer after having installed the software.
  • Seite 15: Register Config, Hw Identification And Serial Number

    LCD Contrast value (High-Byte)* LCD Contrast value (Low-Byte)* Display mode The module name is stored in the HW identification register. Here the user can determine the product identity. The hardware identifier ends with a blank (20 Register SERIAL NUMBER serves for internal purposes and can only be read by the user. *: EXDUL-336E only! EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 16: Memory Areas Usera, Userb, Userlcd1M* And Userlcd2M

    UserLCD-line1 and UserLCD-line2 are not retained when switching off. You can adjust the LCD display contrast in the register LCD contrast. This adjust- ment is also retained stored when the diveice is switched off. EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 17: Index Of Commands

    Reading counter1 01 23 00 Reading counter2 81 03 ww Writing relay output port 82 kk 0x Writing of single relay outputs 83 kk 0x Reading of single relay outputs EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 18 Writing output port reset value A3 03 mm Writing display mode byte* A8 ww ww Writing LCD contrast setting value* AF xy ww Writing user LCD area* *: EXDUL-336E only! EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 19: Structure Of Commands

    Areas User A and User B each comprise of 16 digits (16 bytes), both areas are written byte by byte. For example: Write the word STEUERUNG in User area A Write Return EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 20 15 Operation code E0 configuration EC HW identifier user area A user area B serial number All above-mentioned areas comprise of 16 digits each (16 bytes) and are read byte by byte. Hardware identifier ends with a blank character (20 EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 21 EC HW identifier user area A user area B serial number For Example: Reading the first 9 digits of the register user area A. The indicated response is valid for the word STEUERUNG (see example in section 6.9.1 Writing in User Area A) Read Response EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 22 (0 = Low = 0...3 V; 1 = High = 10...30 V) Input channel IN09 IN08 IN07 IN06 IN05 IN04 IN03 IN02 IN01 IN00 Terminal screw Input level Display* Write Response *: EXDUL-336E only EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 23 Reading value_1 input level = 0 input level = 1 nput number Number of optocoupler input pin (e.g. 00 = IN0) Operation code Reading of single inputs *: EXDUL-336E only! EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 24 (relay contact made = 1; relay contact broken = 0) Output channel OUT07 OUT06 OUT05 OUT04 OUT03 OUT02 OUT01 OUT00 Terminal screw Switching status Display* Write Response *: EXDUL-336E only! EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 25 Transfer value of output level relay contact broken relay contact made Operation code Number of relay contact output pin 00 .. 07 Operation code Writing output port *: EXDUL-336E only! EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 26 Adapter Response Reading value_1 Output not enabled Output enabled Number of output Number of relay contact output pin (e.g. 00 = OUT0) Operation code Reading of single outputs *: EXDUL-336E only! EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 27 1 x x x x counter1 start at reset 0 x x x x counter1 no start at reset Bit 0 to 3 as well as bit 6 and 7 are reserved. EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 28 Counter1 and counter2 are 16bit counters with a counting range of 0 ..65535. Every start command will reset the selected counter to 0 and then it will start to count upwards. EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 29 Operation code Reading counter value counter value = reading value_2 x 256 + reading value_1 For example: Reading counter value 2047 on counter1: Response Display* Write L1: 2047 *: EXDUL-336E only EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 30 ). The Display* will show an „F“ before the count value („Fehlerüberlauf“ - value range exceeded). For example: Read counter value 2047 on counter2 after the count range being exceeded Response Display* Write L1: F 2047 *: EXDUL-336E only! EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 31 (relay contact made = 1; relay contact broken = 0) Output channel OUT07 OUT06 OUT05 OUT04 OUT03 OUT02 OUT01 OUT00 Terminal screw Switching status Display* Write Response *: EXDUL-336E only! EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 32 6.9.12 Writing Display Mode Byte* Transfer value I/O mode UserLCD mode Operation code Config register Operation code A3 Writing Display modus byte (Config register Byte 4) The display mode byte determines, which data is displayed in a flashing or rotati- onal mode, respectively, alternating with communication or refresh display. *: EXDUL-336E only! EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 33 Contrast value = transfer value high-byte x 256 + transfer value low-byte (0F FF = 4095) For example: Display contrast peak value (maximum brightness) Write Response Display contrast average value Write Response *: EXDUL-336E only! EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 34 Writing UserLCD-Line 1 Writing UserLCD-Line 2 Writing UserLCDm-Line 1 Writing UserLCDm-Line 2 Reading UserLCD-Line 1 Reading UserLCD-Line 2 Reading UserLCDm-Line 1 Reading UserLCDm-Line 2 Operation code User LCD Area *: EXDUL-336E only! EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 35 ® For example: Write the word STEUERUNG into UserLCD-Line 1 Write Response Calling the command A3 induces the display to show the UserLCD area *: EXDUL-336E only! EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 36: Specifications

    Counting frequency: max. 5 kHz LCD Display (EXDUL-336E only) Display: Matrix display with 2 lines and 16 columns performing 16 characters each line Programmable as. I/O status display UserLCD display EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 37 Insulated casing with integrated snap-on technology for DIN EN top-hat rail mounting Suitable for control and engineering technology mounted to control and distribution boxes, for surface mounting or mobile use on a desk. EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 38: Examples For Circuitry

    = „0“ circuit breaker closed = „1“ EXDUL-336 Circuit breaker IN00+ + 24V (V IN01+ IN02+ IN03+ IN04+ IN05+ IN06+ IN007+ IN08+ IN09+ IN00...09- (GND Principle circuit diagram EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 39: Wiring Of The Outputs

    (GND e.g. lamp OUT05A Electr. Load (GND e.g. lamp OUT06A Electr. Load (GND e.g. lamp OUT07A Electr. Load (GND e.g. lamp OUT00...07B + 24V (V Principle circuit diagram (common V EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 40 Electr. Load + 24V (V e.g. lamp OUT06A Electr. Load + 24V (V e.g. lamp OUT07A Electr. Load + 24V (V e.g. lamp OUT00...07B (GND Principle circuit diagram (common GND) EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 41: Ascii Table

    00011011 01000011 00011100 01000100 00011101 01000101 00011110 01000110 00011111 01000111 00100000 [Blank] 01001000 00100001 01001001 „ 00100010 01001010 00100011 01001011 00100100 01001100 00100101 01001101 00100110 & 01001110 ‚ 00100111 01001111 EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 42 01101101 10011001 01101110 10011010 01101111 10011011 01110000 10011100 01110001 10011101 01110010 10011110 01110011 10011111 01110100 10100000 01110101 10100001 01110110 10100010 01110111 10100011 01111000 10100100 01111001 10100101 01111010 10100110 01111011 10100111 EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 43 11000101 11110001 11000110 11110010 11000111 11110011 11001000 11110100 11001001 11110101 11001010 11110110 11001011 11110111 11001100 11111000 11001101 11111001 11001110 11111010 11001111 11111011 11010000 11111100 11010001 11111101 11010010 11111110 11010011 11111111 EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 44: Release Notes

    Firmware Version 4.05 • Speed optimization • Reset command removed • Modifications upon accessing to the LCD display • New commands for accessing to single relay channels and for rea- ding of the relay output port EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 45: Product Liability Act

    Especially the following instructions must be observed: VDE100; VDE0550/0551; VDE0700; VDE0711; VDE0860. The instructions are available from: Vde-Verlag GmbH Bismarckstr. 33 10625 Berlin EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 46 The compliance with building and safety instructions of every kind (VDE, TÜV, industrial injuries corporation, etc.) are entirely subject to the user/ customer. EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 47: Ce Declaration Of Conformity

    EN 50082-1 EN 60555-2 EN 60555-3 The following manufacturer is responsible for this declaration: Messcomp Datentechnik GmbH Neudecker Str. 11 83512 Wasserburg given by Dipl.Ing.(FH) Hans Schnellhammer Wasserburg, 29.10.2008 ________________________________ EXDUL-336E / EXDUL-336S © 2009-2015 by Messcomp Datentechnik GmbH EV06...
  • Seite 48 ® Reference System for Intended Use The multi functional modules EXDUL-336E and EXDUL-336S are not stand-alone devices. The CE-conformity only can be assessed when using additional computer components simultaneously. Thus the CE conformity only can be confirmed when using the following reference system for the intended use of the multi functional modules:...

Diese Anleitung auch für:

Exdul-336s

Inhaltsverzeichnis