00424A SCC-B2307P-eng 4/7/05 9:11 PM ˘ ` 10
DAY/NIGHT External Signal Input & Alarm Signal Output
This is a function to receive the external DAY/NIGHT signal from the
sensor(option) and convert the signal into BW. The MOTION DET
E
function generates an alarm signal when a movement is detected.
Connect an external sensor to the DAY/NIGHT terminal as shown in
connect any external device such as a buzzer or lamp to the ALARM
terminal as shown in .
The ALARM output terminal is an open collector with the following capacity:
DC 16V and 100mA.
OFF : Open contact
ON : Below 100mA
The DAY/NIGHT input terminal has the input of DC 5V pull-up and over
0.2mA.
OFF : Open contact
ON : Closed contact
10
All manuals and user guides at all-guides.com
DAY/NIGHT IN
GND
ALARM OUT