Herunterladen Inhalt Inhalt Diese Seite drucken

Conversion Instructions - Dru ART 2-01 Umbauinstruktionen

Vorschau ausblenden Andere Handbücher für ART 2-01:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 9

CONVERSION INSTRUCTIONS

The conversion should be performed
by a recognised installer.
1. Close the gas supply pipe.
2. Remove the mantelpiece.
If the right side of the appliance is
difficult to reach:
3. Disconnect the gas supply pipe.
4. Move the appliance away from the
wall.
Changing the parts:
Art 2-01, 3-01, 4-01, 5-01, 6-01,
8-02, 10-02/ Style 3-01, 4-01,
5-01
5. Pilot burner injector
Loosen the pilot burner gland nut
at the end of the pilot burner pipe,
pull the pilot burner with catch out
of the pilot burner and remove the
pilot burner injector. Place new
pilot burner injector and firmly
tighten the pilot burner gland nut of
the pilot burner pipe.
Art 2-01/ Style 3-01
6. Main burner injector
Loosen the gland nut around the
injector. Also loosen the gland nut
in the gas control by a few turns.
Then pull the supply gas pipe out
of the injector and turn it away
from the injector. Use an open-end
wrench to unscrew the knee-piece
and injector out of the burner,
remove the injector from the knee-
piece and place the new injector.
Finally, reconnect the parts in
reverse order.
Art 3-01, 4-01, 5-01, 6-01, 8-02,
10-02/ Style 4-01, 5-01
6. Main burner injector
Loosen the gland nut around the
injector. Also loosen the gland nut
in the gas control by a few turns.
Then pull the supply gas pipe out
of the injector and turn it away
from the injector. Use an open-end
wrench to unscrew the injector
from the burner and place the new
injector. Finally, reconnect the parts
in reverse order.
Art 2-01, 3-01, 4-01, 5-01, 6-01,
8-02, 10-02/ Style 3-01, 4-01,
5-01
7. Low setting injector
If necessary, unscrew the gas
control from the appliance.
Unscrew the low setting injector
(3) from the gas control. Place the
new low setting injector and tighten
firmly.
Art 2-01, 3-01, 4-01, 5-01, 6-01,
8-02, 10-02/ Style 3-01, 4-01,
5-01
8. Setting the burner pressure
Reconnect the gas supply pipe to
the appliance and open the supply
of new gas. The gas control has a
pressure gauge point, making it easy
to check the burner pressure by
means of a manometer. Loosen the
pressure gauge point screw (4) and
connect the manometer.
For conversion to propane or
natural gas, the burner pressure
must be set by means of the
12

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis