Herunterladen Inhalt Inhalt Diese Seite drucken

Led Display - Balluff BTL7-S5xx-Mxxxx-A/B-SA211-S32/S147/KAxx/FA serie Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BTL7-S5 _ _ (B)-M _ _ _ _ -A/B(8)-SA211/SA311-S32/S147/KA _ _ /FA _ _
Micropulse Transducer - Rod Style
3
Construction and function (continued)
3.3

LED display

LED 1
LED 2
Fig. 3-2:
Position of the BTL7 LED displays
LED 1
Normal function
Green
Magnet is within the limits.
Red
Error
No magnet or magnet outside the limits.
LED 2
Green
Synchronous operation
Internal measurement is synchronous to SSI query.
Off
Asynchronous operation
Internal measurement is asynchronous to SSI query.
Programming mode
Flashing
green
Only with BTL7-S510(B)-...
Note on configuration
(only BTL7-S510(B)-...)
The entire range of functionality can only be
configured with the PC software "Micropulse
Configuration Tool". To do this, the USB
communication box must be connected
(see Accessories on page 23).
When reading or writing data via the Micropulse
Configuration Tool, LED 2 flashes green to display
programming mode.
1) Asynchronous operation is reached when the external sampling rate is
> f
or < 62.5 Hz (only with BTL7-S5_ _B-...), see Technical data on
A,max
page 20, Fig. 8-1.
8
english
1)
1)
Behavior of LED 1 and the error value through the entire
range:
SSI
out
LED
21
2
Magnet
missing
≈ 5 mm
0
Null point
Fig. 3-3:
Behavior of LED 1 and error value BTL7 ≥ 5 µm
For resolutions ≥ 5 µm, in the case of an error, bit 2
set. For resolutions < 5 µm, there is no error bit and the
value 0 is output.
Pos
End point
is
21