Herunterladen Inhalt Inhalt Diese Seite drucken

Regulations To Be Observed; Technical Data; Foreword - Olsberg Iriga Compact 23/645 Anleitung

Vorschau ausblenden Andere Handbücher für Iriga Compact 23/645:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Stove Iriga Compact
Table of Contents
Foreword ................................................................. 10
Technical Data ........................................................ 10
Regulations to be observed .................................. 10
Chimney design ...................................................... 11
Combustion air supply ........................................... 11
combustion air connection .........................................11
Installing the stove ................................................. 11
Assembly sequence ..................................................11

Foreword

Operation ................................................................. 12
Permissible fuels ...................................................... 12
Igniting ...................................................................... 12
Combustion air slide valve........................................ 13
Regulation of combustion air .................................... 13
Fire grate .................................................................. 13
Wood storage compartment ..................................... 13
Heating ..................................................................... 14
Heating during the transition period.......................... 14
Cladding .................................................................. 14
Special information ................................................ 14
Cleaning .................................................................. 14
in the combustion chamber ................................... 15
Replacement parts ................................................. 15
What to do if ...? ...................................................... 15
product.
A large degree of user comfort and high fuel utilisa-
ing, without having to do without the cosy atmosphere
Proper installation and correct handling and care are
indispensable for problem-free operation and a long
service life. Please therefore observe all the informa-
tion given in these instructions. We are convinced that
you will then derive a great deal of pleasure from this
stove. Please keep these instructions in a safe place
so that you can read through them at the start of each
heating period.
to your supplier immediately as otherwise it will not be
possible to correct the damage free of charge.
10
This stove is a top quality modern heating technology
tion enable it to be used as high quality space heat-
of an open fire.
Should you find any transport damage, please report it

Technical Data

Regulations to be observed

● Nominal thermal output ................................. 5,0 kW
● Room heat output .......................................... 5,0 kW
● Height to middle of the connector pipe
with the connection is at the back ..............1178 mm
● Height to the top edge of connector pipe
with the connection at the top .................... 1319 mm
● Connection pipe ...................................... Ø 150 mm
● max. Weight................................................... 190 kg
● Height to middle
of combustion air connection ....................... 360 mm
● Connection combustion air ...................... Ø 125 mm
● Operating mode ........................ Intermitting burning
● Local and building law regulations
● The stove must be installed by a professional and
ulations for safe installation of the connector must be
complied with. The connecting piece used must pos-
sess an opening for cleaning.
● The stove must be regularly checked by a
professional.
● The stove has national technical approval from the
Deutsches Institut für Bautechnik (DIBt) (German
Institute for Civil Engineering) for room-air independ-
ent operation.
Due to its general technical approval, the stove
Iriga Compact can be used simultaneously with
an approved ventilation system without addition-
al safety device.
fore approved for connection to chimneys with multiple
connections.
connected to the chimney. The specific national reg-
The heating stove's fire door is self­closing; it is there-