Herunterladen Inhalt Inhalt Diese Seite drucken

ELRO EQUAJET Installationsanleitung Seite 27

Vorschau ausblenden Andere Handbücher für EQUAJET:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3E-490043NI – 03/20
6 AND 10 LEVEL OVENS ON A STAND
The required height of the loading threshold is 900mm. Fig. 2.1B
If the oven is fitted with a hood it must be fixed to the floor. The rear legs must be fixed using the two stainless brackets provided with the
stand they should be fitted to the rear legs. Fig. 2.1C
TWIN CAVITY OVENS
The required height of the loading threshold is 290mm on 6+6 and 6+10 ovens. Fig. 2.2A
If the oven is fitted with a hood it must be fixed to the floor. The rear legs must be fixed using the two stainless brackets provided with the
stand they should be fitted to the rear legs Fig. 2.2B
20 LEVEL OVENS AND TWIN CAVITY OVENS
The required height of the loading threshold is 355mm. Fig. 2.3A
20 level GN1/1 ovens must always be fixed to the floor. The oven must be fixed to the floor using the bracket supplied with the oven. Fit a
bracket to the left rear legs. Fig. 2.3B
INSTRUCTION FOR HOT CONTAINERS
Maximal height for loading is 1600mm from the ground. A sticker is delivered with the instructions manual. Place the sticker on the Combi
oven at 1600mm from the ground. Fig. 8A
Danger: For containers that are filled with liquid or food that liquefies during the cooking process, operators must be able to see the
contents of the container if it is inserted any higher.
ELECTRICAL CONNECTION
The fixed electrical supply to the unit must incorporate an appropriate isolator that can be locked in the off position.
All aspects of the installation should be in compliance with current local regulations.
The appliance must be connected to earth.
These instructions include recommendations concerning the characteristics and the type of additional protective devices that may
need to be installed, potentially one or several residual current devices.
Electric connection is carried out at the rear of the appliance on the right, whatever the model: Fig. 5A-B
- Remove the right hand panel.
- Pull the cable through the gland.
- Connect the wires (check the neutral and the earth).
- Tighten the gland.
- Refit the side panel.
- Connect the equipotential link to the terminal provided for this purpose. Fig. 5D
• Only use H07 RN-F type supply cable sized to suit the load of the unit. (see chapter « technical characteristics » which give the electrical
rating).
Provide an approved omnipolar isolation device, (with at least 3 mm clearance between the contacts).
ENERGY ECONOMIZER CONNECTION
6 and 10 level ovens (optional)
Only use HO 7 RNF type supply cables with a section of 5 x 1.5 mm2.
A local and approved isolation devise is required for the energy saver (with at least 3mm clearance between all contacts when open).
Dangerous voltages may be present in the appliance in case of inappropriate installation.
Connection of the energy saver on 20 level units:
The installation must meet current national statutory provisions (France: NFC 15.100)
Use H07 RN-F type 1.5mm² cables with the number of cores required by the energy saver.
Pass the cable(s) through the cable glands on the connector support and through the outer grommets on the electrical support:
Remove the cable bridges B1-C1 and B2-C2 when connecting the energy saver to these terminals.
Page 3
LOCATION
CONNECTIONS
EN
ELRO-Werke AG
Wohlerstrasse 47
5620 Bremgarten

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für ELRO EQUAJET

Inhaltsverzeichnis