Herunterladen Diese Seite drucken
Oregon Scientific EMR201 Bedienungsanleitung

Oregon Scientific EMR201 Bedienungsanleitung

Funkthermometer innen/außen mit led-frostwarnung
Vorschau ausblenden Andere Handbücher für EMR201:

Werbung

FIG. 1
1
���������
FIG. 2
1
2
C/ F
RESET
FIG. 3
2
1
3
FIG. 4
Wireless Indoor and Outdoor Thermometer
with LED Ice Alert
Model: EMR201
USER MANUAL
EN
OVERVIEW
FRONT VIEW – FIG. 1
1. Remote sensor reception indicator
2. Outdoor temperature
2
3. Indoor temperature
4. Ice alert LED indicator
BACK VIEW – FIG. 2
3
1. °C / °F: Select temperature unit
2. RESET: Reset unit to default settings
4
REMOTE SENSOR – FIG. 3
1. LED status indicator
2. Wall mount hole
3. Battery compartment
4. RESET hole
5. CHANNEL switch
GETTING STARTED
INSERT BATTERIES
1. Remove the battery compartment.
2.
Insert the batteries, matching the polarities (see FIG 2).
3. Press RESET after each battery change.
LOCATION
LOCATION
Indoor temperature
area
Outdoor temperature
area
REMOTE SENSOR
To set up the sensor:
1. Open the battery compartment (see FIG 3).
2. Select channel 1 then press RESET.
3. Close the battery door.
4. Place the sensor within 30 m (98 ft) of the main unit
using the table stand or wall mount.
TIP
Ideal placements for the sensor would be in any
location on the exterior of the home at a height of not more
than 5 ft and which can shield it from direct sunlight or wet
conditions for an accurate reading (see FIG. 4).
4
5
NOTE
Use alkaline batteries for longer usage and
consumer grade lithium batteries in temperatures below
freezing.
SENSOR DATA TRANSMISSION
To search for a sensor:
Reset the unit.
The sensor reception icon in the remote sensor area
shows the status:
ICON
ICON
OUT
OUT
OUT
OUT
OUT
OUT
OUT
TIP
The transmission range may vary depending on
many factors. You may need to experiment with various
locations to get the best results.
ICE WARNING
If the channel 1 sensor falls between 3°C to -2 °C (37°F to
28°F), LED indicator will fl ash, and will stop fl ashing once
the temperature is out of this range.
RESET
Press RESET to return to the default settings.
PRECAUTIONS
Do not subject the unit to excessive force, shock, dust,
temperature or humidity.
MEANING
MEANING
Main unit batteries low
Sensor batteries low
DESCRIPTION
Main unit is searching
for sensor(s).
A channel has been
found.
The sensor cannot be
found.
Do not cover the ventilation holes with any items such
as newspapers, curtains etc.
Do not immerse the unit in water. If you spill liquid over
it, dry it immediately with a soft, lint-free cloth.
Do not clean the unit with abrasive or corrosive
materials.
Do not tamper with the unit's internal components.
This invalidates the warranty.
Only use fresh batteries. Do not mix new and old
batteries.
Images shown in this manual may differ from the
Images shown in this manual may dif
Images shown in this manual may differ from the
actual display.
When disposing of this product, ensure it is collected
separately for special treatment.
Placement of this product on certain types of wood
may result in damage to its fi nish for which Oregon
Scientifi c will not be responsible. Consult the furniture
manufacturer's care instructions for information.
The contents of this manual may not be reproduced
without the permission of the manufacturer.
Do not dispose old batteries as unsorted municipal
waste. Collection of such waste separately for special
treatment is necessary.
Please note that some units are equipped with a
battery safety strip. Remove the strip from the battery
compartment before fi rst use.
NOTE
The technical specifi cations for this product and
the contents of the user manual are subject to change
without notice.
SPECIFICATIONS
TYPE
TYPE
DESCRIPTION
DESCRIPTION
MAIN UNIT
L x W x H
66 x 27.5 x 87.5 mm
(2.59 x 1.08 x 3.44 in)
Weight
241 g (8.5 oz) without battery
Temperature range
-5°C to 50°C (23°F to 122°F)
Resolution
0.1°C (0.2°F)
Signal frequency
433 MHz
Power
2 x UM-4 (AAA)
1.5 V batteries
REMOTE UNIT (THN132N)
L x W x H
96 x 50 x 22 mm
(3.78 x 1.97 x 0.87 in)
Weight
62 g (2.22 ounces)
Transmission range
30 m (98 ft) unobstructed
Temperature range
-20°C to 60°C (-4°F to 140°F)
Power
1 x UM-3 (AA) 1.5 V batteries
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientifi c.com
www.oregonscientifi c.com) to learn more
about Oregon Scientifi c products. If you're in the US and
would like to contact our Customer Care department directly,
please visit: www2.oregonscientifi c.com/service/support
www2.oregonscientifi c.com/service/support
OR
Call 1-800-853-8883.
For international inquiries, please visit:
www2.oregonscientifi c.com/about/international
www2.oregonscientifi c.com/about/international
EU-DECLARATION OF CONFORMITY
Hereby, Oregon Scientifi c, declares that this Wireless
Indoor and Outdoor Thermometer with LED Ice Alert
(Model: EMR201) is in compliance with the essential
requirements and other relevant provisions of Directive
1999/5/EC. A copy of the signed and dated Declaration
of Conformity is available on request via our Oregon
Scientifi c Customer Service.
COUNTRIES RTTE APPROVED COMPLIED
All EU countries, Switzerland CH
FCC STATEMENT
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) This
device must accept any interference received, including
interference that may cause undesired operation.
CH
and Norway
N
N

Werbung

loading

Inhaltszusammenfassung für Oregon Scientific EMR201

  • Seite 1 Hereby, Oregon Scientifi c, declares that this Wireless Indoor and Outdoor Thermometer with LED Ice Alert The sensor cannot be (Model: EMR201) is in compliance with the essential found. requirements and other relevant provisions of Directive 1999/5/EC. A copy of the signed and dated Declaration...
  • Seite 2: Manuale Per L'utente

    Termómetro inalámbrico interior y exterior con alarma essenziali ed alle altre disposizioni pertinenti stabilite Impossibile trovare il de hielo LED(Modelo: EMR201) cumple con los requisitos dalla direttiva 1999/5/CE. Una copia fi rmata e datata della sensore. AVISO DE HIELO esenciales y cualesquiera otras disposiciones aplicables Dichiarazione di Conformità...
  • Seite 3: Eu-Konformitätserklärung

    Con la presente Oregon Scientifi c dichiara che questo können. Für internationale Anfragen besuchen Sie bitte unsere È stato rilevato un canale. prodotto (Modello: EMR201) è conforme ai requisiti Un canal a été trouvé. Un canal a été trouvé. Un canal a été trouvé.
  • Seite 4 Temperaturwerte wieder den grundlegenden Anforderungen und anderen relevanten à gel (Modèle: EMR201) est conforme aux exigences essentielles außerhalb dieses Bereichs befi nden. Se la temperatura rilevata dal sensore posizionato Vorschriften der Richtlinie 1999/5/ EG übereinstimmt. Eine et aux autres dispositions pertinentes de la directive 1999/5/CE.
  • Seite 5 EMR201) voldoet aan de essentiële eisen en aan de Fjärrenheten kan inte hittas. Fjärrenheten kan inte hittas. Fjärrenheten kan inte hittas. Fjärrenheten kan inte hittas.
  • Seite 6 Oregon Scientifi c declara que este(a) Termômetro sem fi o Het apparaat zoekt sensor(en). Het apparaat zoekt sensor(en). inomhus och utomhustermometer med LED frostvarning (Modell: EMR201) voldoet aan de essentiële eisen en aan de Fjärrenheten kan inte hittas. Fjärrenheten kan inte hittas. Fjärrenheten kan inte hittas.