Herunterladen Inhalt Inhalt Diese Seite drucken

Campingaz Camp Bistro Stopgaz Bedienungsanleitung Seite 8

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 11
Consumption: 160 g/h (2.2 kW)
Category: butane direct pressure
thank you for choosing this Campingaz® CAMP'BISTRO
STOPGAZ™
GB
A - IMPORTANT: YOU ARE USING GAS, BE vERY CAREFUL!
the purpose of these instructions is to enable you to use
your Campingaz® CAMP'BISTRO STOPGAZ™ correctly and
in complete safety.
Please read them carefully to familiarise yourself with
the equipment prior to assembling the gas container.
Keep these instructions in a safe place so that you can
refer to them if needed.
Please observe these instructions and the safety
measures printed on the Campingaz® CP250/ CP250 SP
cartridges. Failure to observe these instructions may
result in the user and people in the immediate vicinity
being put at risk.
This equipment must be used exclusively with
Campingaz® CP250/ CP250 SP cartridges. Using other
gas containers may be dangerous.
The Société Application Des Gaz accepts no
responsibility when cartridges of any other make are
used.
Your stove should only be used in premises with
sufficient ventilation (minimum 2m
from inflammable materials.
This stove is not connected to a combustion product
evacuation system. It should be installed and
connected in accordance with installation rules in
force. Particular care should be given to applicable
provisions regarding ventilation.
Using a gas cooking stove produces heat and humidity
in the room where it is installed. Make sure the kitchen
is well ventilated: keep natural ventilation sources
open or install a mechanical ventilation system
(mechanical ventilation hood). Intensive, prolonged
use of the stove may require additional ventilation,
for example by opening a window, or more efficient
ventilation, for example by increasing the power of
the mechanical ventilation if it exists.
Do not use equipment which leaks, functions incorrectly
or is damaged. Return it to your retailer who will inform
you of your nearest after-sales service.
Never modify this equipment or use it for purposes for
which it is not intended.
Do not use this product in caravans, cars, tents, huts,
sheds or any small enclosed areas.
The product should not be used while sleeping or left
unattended.
This product consumes fuel through combustion
or consumption of oxygen and gives off certain
substances and gas, which could be dangerous such as
carbon monoxide.
Carbon monoxide is an odorless, clear gas that can
cause flu-like symptoms, sickness, illness, and possibly
death if produced inside aforesaid enclosed areas
through use of the product without proper ventilation.
If the cartridge is automatically ejected from the
regulator, DO NOT CONNECT THE CARTRIDGE AGAIN,
let the appliance cool down completely before any
use.
Do not use a container smaller than 12cm or larger than
26cm in diameter. Do not use vessels with concave or
convex bottoms. Do not use griddles, plancha or stone
on the product except specific Campingaz® accessories
developed for this product.
B - PREPARATION FOR OPERATION
- Remove the device from its packaging.
Figures: see pages 2 to 4
/h/kW) and away
3
8
Installing a CAMPINGAZ® cartridge CP250/ CP250 SP
(When the existing cartridge is empty, read paragraph D:
"Changing the cartridge")
to install or remove a cartridge, always work in a well-
ventilated area, preferably outside and never in the
presence of a flame, heat source or spark (lit cigarette,
electrical equipment, etc.) at a good distance from other
people and flammable material.
aS CamPingaz® CP250/ CP250 SP CaRtRiDgeS have
vaLveS, even if they aRe not emPty, they may
Be RemoveD fRom thiS eQuiPment to maKe it
eaSieR to tRanSPoRt, anD they may Be fitteD to
otheR eQuiPment fRom the CamPingaz® CP250/
CP250 SP Range WhiCh aRe DeSigneD to oPeRate
exCLuSiveLy With theSe CaRtRiDgeS.
- open the cartridge cover (3) (fig. 2).
- Check that the ignition button (1) is set to position "l" by
turning it clockwise and that the lever (2) is set to unLoCK
(fig. 3).
Comment: the gas cartridge can only be locked if the ignition
button is in position "l" and the pan support is in place.
- Check that the seal between the appliance and the
gas container is in place and in good condition before
connecting the gas container (see figure 4). Do not use
this appliance if it has damaged or worn seal.
- install the cartridge in its housing, slot "f" facing upwards,
and engage the cartridge guide "g" firmly into the slot
(fig. 5).
- Lock the cartridge by moving the lever (2) to the LoCK
position (fig. 6). Close the cartridge compartment cover (3).
the equipment is ready for use.
CAUTION: make sure the cartridge slot "f" is pointing
upward and inserted in the cartridge guide "g".
incorrect positioning of the gas cartridge (8) will cause the
regulator to break and/or gas leakage, producing a hissing
sound and gas smell.
in case of leakage (gas smell before opening the valve), put
immediately the equipment outside, in a well-ventilated
area, without inflammation source, where it will be possible
to locate and stop the lead. if you wish to check the tightness
of the equipment, do it outside. Do not try to locate a leak
with a flame, use gas leak detection liquid.
C - USE
Additional instructions:
Do not use your stove at a distance closer than 20 cm
to a wall or flammable object, nor closer than 1 meter
to a ceiling.
WARNING: Accessible parts may be very hot. Keep
young children away.
Never touch the pan support (4) or the burner (5)
during or just after using the equipment.
Do not obstruct the ventilation hole (7) in the cartridge
compartment cover (3).
Never use pans which cover the burner entirely (5).
Position the equipment on a stable, horizontal surface
and do not move when in use.
Wait until the appliance has completely cooled down
before handling and putting it away.
Any room or kitchen where you use your stove must
comply with regulatory ventilation conditions that
supply air required for combustion and prevent the
creation of mixes with a dangerous level of unburned
gas (2m
/h/kW).
3

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis