HERMETIC BELL PUSH PDJ-213
• surface mounted push button with door plate
• plastic casing
• intended for both doorbell and intercom wiring
• possibility of the control of solenoid lock or other L.V.
devices
• adapted for operation under heavy duty and variable
ambient conditions (ex. at the gate/wicket)

TECHNICAL SPECIFICATIONS

Power supply, power consumption: 1 A/ 250 V AC
Protection class: II
IP protection: IP 44
Operating temperature range : - 20º C to + 35ºC

INSTALLATION INSTRUCTIONS

1. It is recommended that the push button is installed by a
competent individual appropriately qualified and authorised
2. Prise the cover at its side edges, remove the hole plug
together with the door plate.
3. Unscrew the screw which fastens the push button cover.
4. Remove the appropriate fuse (ex. by screwing it out) from
the power supply circuit and disconnect power supply. If
wiring flat overcurrent-brake switches are used, just switch
in to "0" (OFF) position.
5. NOTE! Make sure using a voltmeter if the power supply
circuit has been isolated from the doorbell wiring.
6. Thread the connection leads (of the cross-section area
0,35mm
2
base.
7. Fasten the bottom part of the casing to the wall or other
object surface with screws.
8. Connect the ends of the leads to the terminals.
9. Replace the push button casing along with the door plate.
10. Switch on bell installation power supply.
11. Press down the doorbell push button and check how it
operates.