STARTING THE SEASON
The pH probe is calibrated form the factory the first time it is used; therefore no calibration is ne-
eded at the initial startup of the unit.
When starting a new season with the pH probe or after any change of the probe, it is of most impor-
tance to calibrate pH probe to insure an optimal pH regualtion of the water.
This is how it is done:
1. Unscrew then remove the nut and pH probe from the probe holder. Use provided plug to seal
orifice.
2. Press 3 sec on C, the LED flashes
3. Put the pH probe in a pH 7 solution (not
provided). The standard solution should
only be used once. Cast it after use.
4. Press 3 sec. on C, the LED flashes while
calibrating the probe.
5. When the probe is calibrated, the LED
above 7.0 stops flashing. The device is now ready for the actual pH reading of the pool water.
If the LOW LED shines, at the same as one of the green LEDS, it is beacause the probe is worn
and needs to be changed. Contact the manufacturer to get a new probe, and make a new calibration.
In case of wrong manipulation, a cancellation is possible by pressing 3 sec. on D.