Read the instructions carefully before using the product and store
them for future use
GENERAL SAFETY REGULATIONS
If correctly installed and used, the 739 automated system will en-
sure a high degree of safety. Some simple rules on behaviour can
prevent accidental trouble:
Do not stand near the automatic system, and do not allow children,
persons or things to do so, especially when it is operating.
Keep radio-controls, or any other pulse generators that could involunta-
rily activate the automated system, well away from children.
Do not allow children to play with the automated system.
Do not willingly obstruct gate movement.
Prevent any branches or shrubs from interfering with gate movement.
Keep the indicator-lights efficient and easy to see.
Do not attempt to activate the gate by hand unless you have released
it.
In the event of malfunctions, release the gate to allow access and wait
for qualified technical personnel to do the necessary work.
When you have set manual operation mode, cut power to the system
before restoring normal operation.
Do not in any way modify the components of the automated system.
Do not attempt any kind of repair or direct action whatever and con-
tact qualified personnel only.
At least every six months: arrange a check by qualified personnel of the
automatic system, safety devices and earth connection.
DESCRIPTION
The 739 automated system is ideal for controlling vehicle access areas
in residential environments.
739 for sliding gates is an electro-mechanical operator which transmits
motion to the leaf via a rack and pinion.
For details on sliding gate behaviour in different function logics, consult
the installation Technician.
Automated systems include obstacle detection devices (photocells)
that prevent the gate from closing when there is an obstacle in the
area they protect.
The system ensures mechanical locking when the motor is not operating
and, therefore, installing a lock is unnecessary.
Manual opening is, therefore, only possible by using the release system.
The gearmotor has an adjustable electronic clutch enabling safe use of
the automated system.
The control unit is built into the gearmotor.
A handy manual release facility makes it possible to move the gate in
the event of a power cut or fault.
The warning-light indicates that the gate is currently moving.
TECHNICAL SPECIFICATIONS
MODEL
Power supply (+6% -10%)
Absorbed power (W)
Absorbed current (A)
Thrust capacitor (µF)
Thrust on pinion (daN)
Torque (Nm)
Temperature protection (°C)
Max leaf weight (Kg)
Type of pinion gear
Gate speed (m/min)
Max. gate length (m)
Type of travel-limit device
Type of clutch
Use frequency
Operating ambient temperature (°C)
Weight of gearmotor (Kg)
Protection class
Operator dimensions
ENGLISH
739 230V
739 24V
230/115V~
230V~ 50Hz
50/60Hz
350
70
1.5
3
10
-
45
40
18
13.5
140
-
500
400
Z16
Z16
12
12
15
15
Mechanical
Mechanical
Electronic
Electronic
S3 - 30%
100%
-20 ÷ +55
-20 ÷ +55
10
8.5
IP44
IP44
See Fig.2
See Fig.2
MANUAL OPERATION
The manual release is a device that makes it possible to disconnect
the operator from the gate, thus enabling manual movement.
Before using the release device, cut power to the system, with the
differential switch upstream of the gearmotor.
THE RELEASE DEVICE MUST NOT BE CONSIDERED AN EMERGENCY STOP
If the gate has to be moved manually due to a power cut or fault of the
automated system, use the release device as follows:
1.
Fit the supplied key in the lock, Fig. 1 Ref.
shown in Fig. 1 Ref.
.
2.
Turn the release system clockwise by about 180°, as shown in Fig. 1 Ref.
.
3.
Open and close the gate manually.
RESTORING NORMAL OPERATION MODE
To prevent an involuntary pulse from activating the gate during
the manoeuvre, cut power to the system before re-locking the
operator.
1.
Turn the release system anti-clockwise by about 180°, as shown in Fig.
2 ref.
.
2.
Turn the key anti-clockwise, Fig. 2 ref.
as shown in Fig. 2 ref.
.
3.
Move the gate until it meshes to release.
Before powering up the system again, make sure that the gate can-
not be moved manually.

MANUTENZIONE

To ensure correct long-term operation and a constant level of safety, we
advise you to generally check the system every 6 months. In the "User's
Guide" booklet, there is a form for recording jobs.
RIPARAZIONI
The User must not in any way attempt to repair or to take direct action
and must solely contact qualified FAAC personnel or FAAC service cen-
tres.
3
, and turn it clockwise as
Fig. 1
Fig. 1
, and remove it from the lock,
Fig. 2
Fig. 2