Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection; How To Use Your Appliance - Fenix ECOFLEX PREMIER Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4. ELECTRICAL CONNECTION

The electrical installation must be equipped with an Omni polar circuit
breaker with a contact opening gap of at least
3 mm.
The pilot wire (black) must never be connected to the earth (yellow-
green wire).
The electrical connection requires no disassembly. The device
should not be installed under a wall socket.
Respect the polarity:
Phase = Brown
Neutral = Blue / Grey
Pilot Wire = Black
If the power cord is damaged, it must be replaced by the manufacturer or
its service agent or a similarly qualified person in order to avoid danger.
Installation:
The electrical installation must comply with standards in the country of
installation
Check the tight fit of the wires into the terminals of the wall outlet.
Note: The instructions for programming are sent by the sidecons signals,
measured from the Neutral.

5. HOW TO USE YOUR APPLIANCE

THE SELECTOR MODE ENABLES 5 FONCTIONS :
FONCTIONS
COMFORT
ECONOMY (SET BACK)
ANTI-FROST
STOP
PROGRAMMATION
ON/OFF SETTING (Picture here under):
To turn on the heater, put the on/off switch (on the side of the appliance) on position 1.
For complete shutdown of the heater, turn the switch to position 0.
HEATING ON/OFF:
To start, push MODE button (picture cons) and the will display comfort temperature
(19).
To stop heating, push MODE button until "- - " (stand-by mode).
Note: Your settings remain in memory; the heater is just on standby.
SCREEN DISPLAY
Displays temperature (e.g. 19)
EC
HG
--
Displays signal of programmer
(function light PROG)
Holds temperature as to thermostat settings.
Holds temperature at ~-3.5°C below comfort temperature.
Holds temperature at ~7°C to avoid frost damage.
Stops all heating functioning.