2.2.1. ELECTRICAL CONNECTIONS AND EQUIPOTENTIAL BONDING FOR THE VERSIONS
Warning! :
The appliance is supplied to operate according to the power supply
indicated on the data plate.
As mentioned, the appliance must be connected to the power supply by way of a multiple pole main
isolating switch and protection device that must be proportioned to the power of the appliance (1 mA per
kW of rated power).
The earthing system must be efficient.
As this appliance is a type X equipment (delivery without power cable and plug), the cable and other
hardware needed to make the connection to the electrical power supply must be provided by the installer.
The power cable shall be of the kind described in the paragraph "Technical data" and shall be resistant
to oil.
Proceed as follows to reach the power supply terminal board:
-
Disconnect the appliance using the switch placed before the appliance.
Remove the fron panel, unloosing the two fixing screws.
Remove the lid of the housing protecting the electrical components.
The cable must be fed in from beneath the clamp. The individual wires are then fastened to the
corresponding terminals of the terminal board. The earth wire must be longer than the other wires, so that
in case of the cable being tugged or the clamp broken, the live wires will disconnect first. Lock the cord
fastener.
The appliance must incorporate an equipotential system.
Connect the terminal on the lower right-hand side marked with the international symbol a connector with
a nominal cross section <10 mm2. All the appliances installed and the earth system of the building shall
be connected like this.
It's strictly forbidden using the pending electric cable connected with terminal board,
overhanging from the frame, to connect definitely the machine.
ATTENTION!
Cut the tension before to make the connection and/or maintenance .
-
Water inlet pressure must be between 50 and 300 kPA, otherwise a pressure regulator must be installed
before the appliance.
-
A water tap is connected to the appliance.
-
The water connection must be in conformity with the Water Act 1086 - Model bylaws.
Manuale d'istruzione per l'installazione, la manutenzione e l'uso
Brasiere a gas ribaltabili BS80.G7 / BS8.G7
MOTORIZED

2.2.2. CONNECTION TO WATERWORKS

05.11.02