Herunterladen Inhalt Inhalt Diese Seite drucken

Backlight; Menu Button Use; High Alarm; Low Alarm - RIDGID micro IR-200 Bedienungsanleitung

Kontaktloses infrarotthermometer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ing the micro IR-200 to ensure good readings. To enable or disable,
while squeezing the trigger, press and release the laser enable but-
ton. The Laser Enable icon will be ON when the laser is enabled.

Backlight

If using in a low lit area, the micro IR-200 is equipped with a display
backlight. To turn the backlight ON and OFF, with the unit ON, press
the backlight button.

Menu Button Use

After squeezing the trigger, pressing and releasing the menu button
will allow you to cycle through the following settings in this order:
High Alarm ON/OFF, High Alarm Temperature Setting, Low Alarm
ON/OFF, Low Alarm Temperature Setting, Temperature Display
Units, Emissivity.

High Alarm

High Alarm will give an audible tone when the current temperature
exceeds a preset limit. To turn the High Alarm ON, squeeze and re-
lease the trigger, and then press and release the menu button until
the High Alarm icon is flashing. Use the up/down buttons to turn the
High Alarm feature ON/OFF as indicated on the current temperature
value line. Press and release the menu button again. The High
Alarm icon will continue to flash, and the High Alarm temperature
will appear. Use the up/down buttons to change the High Alarm tem-
perature as desired. Squeeze the trigger to exit the Settings mode
and save your selection.

Low Alarm

Low Alarm will give an audible tone when the current temperature
falls below a preset limit. To turn the Low Alarm ON, squeeze and re-
lease the trigger, and then press and release the menu button until
the Low Alarm icon is flashing. Use the up/down buttons to turn the
Low Alarm feature ON/OFF as indicated on the current temperature
999-995-066.10_REV. D
micro IR-200 Non-Contact Infrared Thermometer
value line. Press and release the menu button again. The Low Alarm
icon will continue to flash, and the Low Alarm temperature will ap-
pear. Use the up/down buttons to change the Low Alarm tempera-
ture as desired. Squeeze the trigger to exit the Settings mode and
save your selection.
Temperature Display Units - °C/°F
The micro IR-200 can display temperatures in either degrees Celsius
(C) or Fahrenheit (F). To change the display unit, squeeze and re-
lease the trigger, and then press and release the menu button until
the temperature unit on the screen is flashing. Use the up/down but-
tons to switch between F or C as desired. Squeeze the trigger to exit
the Settings mode and save your selection.

Emissivity

The emissivity value can be set from 0.10 to 1.00. See the Set-Up
section to determine an appropriate value for your application. To ad-
just this value, squeeze and release the trigger, and then press and
release the menu button until the emissivity value on the screen is
flashing. Use the up/down buttons to increase or decrease the emis-
sivity value. Squeeze the trigger to exit the Settings mode and save
your selection.

Cleaning

Do not immerse the RIDGID micro IR-200 Non-Contact Infrared
Thermometer in water. Wipe off dirt with a damp soft cloth. Do not
use aggressive cleaning agents or solutions. Treat the instrument as
you would a telescope or camera.

Storage

The RIDGID micro IR-200 Infrared Thermometer must be stored in
a dry secure area between -10°C (14°F) and 60°C (140°F).
Store the tool in a locked area out of the reach of children and peo-
ple unfamiliar with the micro IR-200.
11

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis