Herunterladen Inhalt Inhalt Diese Seite drucken

Dea NET230N Bedienungsanleitung Und Hinweise Seite 52

Programmierbare steuereinheit
Vorschau ausblenden Andere Handbücher für NET230N:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 87
Pedestrian automatic closing time adjustment
(se = 0 pedestrian automatic closing deactivated)
Pedestrian stroke duration adjustment
Pre-flashing time adjustment
Adjustment of phase displacement time while opening
Adjustment of phase displacement time while closing
Collectivity function: if it is activated it deactivates both opening and closing inputs for the whole duration of
automatic opening and closing
Ram blow function: if=0 "Ram blow" function deactivated; if=1 it pushes the motors closed for one second
before each opening movement, so as to ease the releasing of any electric lock; if>1 it execute a periodic
pushing stroke so as to maintain the wings under pressure on the closing strokes. If closing limit switches
are installed, it performs this function only if they are not activated, i.g. when there's a pressure decrease
on the stroke.
"Reversal" mode selection (during the manoeuvre a command impulse reverse the mouvement) or "step by
step" (during the manoeuvre a command impulse stops the mouvement). A next impulse restart the operator
to the opposite direction.
PHOTO 1
PHOTO 2
Operation mode selection of the warning light output:
If = 0 "fix warning light" (output always ON when the gate is open, OFF after a closing operation),
If> 1 "courtesy light" (output ON during each movement, OFF when the motor stops, after the setting delay).
Searches for end of stroke while opening too: when activated, operators stop only at their arrival et the end
of stroke, also while opening.
Warning: During the emergency operation (rESP), the motor executes the first maneuver while opening. In
addition, if any limit switches, the parameter is forced to 1.
"soft start" function: motors accelerate gradually until they reach the set speed, avoiding sudden departures.
Warning: For operators without encoder, the parameter will be ingnored.Attenzione: Per motori senza
encoder, il parametro viene ignorato.
Adjust the inversion on obstacle period (detected by internal anti-crushing sensor or by the safety input when
activated): If = 0 it makes a complete inversion, if> 0 indicates the duration (in seconds) of the run, after
inversion resulting from detection of an obstacle during the opening.
Adjust the inversion on obstacle period (detected by internal anti-crushing sensor or by the safety input when
activated): If = 0 it makes a complete inversion, if> 0 indicates the duration (in seconds) of the run, after
inversion resulting from detection of an obstacle during the closing.
Facilitation manual release: If≠0, after detecting the locking stop, the engine reverses for a brief time to
release the pressure on it, and thus facilitate the manual release. The set value shows the length of the
inversion. If=0 function disabled
50
PHOTO input functioning: If=0: photocell enabled while closing and starting when the gate is
stopped; if=1 photocells are always enabled; if=2 photocells are enabled while closing only.
When enabled, its activation provokes: the inversion (while closing), the stop (while opening)
and prevent the starting (when gate is closed).
If=3-4-5, the operation is the same as the values 0-1-2 but with "close immediately" enabled:
in any case, during the opening and/or the pause time, removal of a possible obstacle causes
the gate automatically closes after a fixed delay of 2 sec.

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für Dea NET230N

Inhaltsverzeichnis