6 STANDARD PROGRAMMING
WARNING For reversible motors with electromagnetic brake, remember to set P062=3.
1 Power Supply
Give power supply, the display shows the following symbols "
*
If the control panel has already been programmed and the power fails or is switched off - once power is returned and a START command
is given, the position reset procedure is performed (see "rESP" in the table "WORKING STATUS MESSAGES" on page 45.
2 Visualisation of inputs and operations-counter status
1. Scroll the parameters with the
screen reads P013;
2. Access the parameter by pressing the
3. The "Input Status" is shown on the screen (check that this
is correct):
4. Press the
button again;
5. The "Total Operation Counter" is shown on the screen
(* see P064):
Ex:
= 3x1000* = 3000 operations executed
6. Press the
button again;
7. The "Maintenance Operation Counter" is shown on the
screen (* see P065):
Ex:
= 5*x500 = 2500 operations still to be car-
ried out before the maintenance intervention request (
= maintenance operation counter disabled)
8. Press the
button again to exit the parameters (P013 is
shown on the screen again).
3 Selection type of operators
1. Scroll down the parameters with
P028;
2. Access the parameter by pressing the
3. Acting on
and
Type 00
Type 01
• 005 6NET
• 001 Look - Mac
• 006 9NET
• 002 Ghost
• 007 Gulliver
• 003 Livi 500
- Rev
- 500MT - 502 -
502EN - 550PL
• 004 Livi 500P -
500MT/RF - 502R
- 502R/EN - 502L
• 005 Oli
Warning: Selecting the OLI operators, all indicated values related to the
operator force (P037 - P038 - P039 - P040), are automatically set to 100%
without any possibility of change. For this type of operator, the obstacle de-
tection is not active and the adjustment of the thrust force can be executed
acting on the operator valves only.
Warning: If you are using non DEA System operators, set the parameter on
the closer value for family type and performances (refer to table on page 30).
4. Confirm your choice by pressing the
P028).
38
and
keys until the
button;
! IMPORTANT !
and
keys until you visualise
key;
keys, set:
Type 02
Type 03
• 003 Livi 902EN
• 003 Pass
• 004 Livi 902R -
• 004 Stop
902R/EN/F
key (display returns again to
", "
", "
" (or the Type selected) and then "- - - - ".
Type 04
• 000 Lato

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für Dea NET230N

Inhaltsverzeichnis