Herunterladen Inhalt Inhalt Diese Seite drucken

Marking And Identification; Installation; Link - Faicom MNR Gebrauchsanweisung

Automatische schlauchaufroller
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6 - MARKING AND IDENTIFICATION

TORINO RENATO
BUSCA (CUNEO) ITALY
MDR200815
20 bar, PU8x12, 15 m
HOSE REEL for AIR
model
duty
serial number
IMPORTANT! Any installation operation shall be carried out by a suitably
trained staff, following carefully the information given in this manual.
Check the packaging at the reception of the goods and store only at a dry place. Verify that
the device has not been damaged during transport or storage operations. Make sure you
receive all the components. Ask the manufacturer for any possible missing component.
The hose reel has to be wall mounted at a minimum height of the floor of 2.50 m in
order to prevent accidents during work operations.
In particular cases it is possible to mount it on the floor or on other machines as accessory,
only if complete with a fixed support if in a protected position.
Mount the hose reel already complete with hose on stiff and consistent walls, using 2 dowels
of 8 mm diameter. Connect the hose reel to the line with the included flexible hose. Put an
air valve on the feed line of the hose reel for ease of maintenance.The air valve can be used
as a safety valve in the event of an accident.
WARNING! The manufacturer declines any responsibility for injuries to people or da-
mages to things caused by a wrong assembly of the hose reel.
We affix the CE marking as the manufacturer of this
equipment.
On the equipment is securely attached a tag with curing
1019
7 kg
adhesive system on which are indicated in addition to
the name of the manufacturer and the symbol "CE", all
information necessary for good identification of the ma-
chine (model, duty, serial number, weight, etc.).
weight

7 - INSTALLATION

8 - LINK

Always connect the hose reel to the line by the couplers
and the flexible hose (A) suitable for this use, above all
in case of high pressure and temperature.
To avoid consequent loss of fluid tighten the fittings
using appropriate keys, keep back the swivel joints (B)
to avoid damaging them.
According to the rules, put a ball-tap on the feeding line of
the hose reels in order to make the maintenance operations
easier. The said ball-tap can be used as a safety valve for
dangerous situations.
- 8 -