19. Specifications
Specifications
Operating conditions
Permissible ambient conditions
■
Humidity
■
Accuracy data
Measuring error
■
Temperature drift
■
Measuring time
■
Measuring rate
■
Memory
Electrical connection
CE conformity
EMC directive
■
WIKA operating instructions digital indicator, model DI32-1
Operation: -20 ... +50 °C
Storage: -30 ... +70 °C
0 ... 85 % r. h. annual mean without condensation
see page 68
100 ppm/K
0.1 ... 20.0 seconds, adjustable
approx. 1/s for temperature sensors
approx. 100/s for standard signals
EEPROM, data preservation ≥ 100 years (at 25 °C)
Removable plug-in terminal, 9-pin
Wire cross-section up to 1.5 mm²
2004/108/EC, EN 61326-1, emission (group 1, class B)
and interference immunity (industrial application)
EN
67