Herunterladen Inhalt Inhalt Diese Seite drucken

Select Frequency Range; Selecting Pulse Length Limiting - WIKA DI32-1 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für DI32-1:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

9. Frequency measurement

9.3 Select frequency range

[☼]
TYPE
[▲] [▼]
rAnG
Parameter
9,999
99.99
999.9
9999

9.4 Selecting pulse length limiting

Debounces mechanical contacts via the filter frequency.
[☼]
TYPE
[▲] [▼]
FILt
Parameter
no
2
5
10
20
50
100
500
WIKA operating instructions digital indicator, model DI32-1
[☼]
9.999
99.99
999.9
9999
Description
0 ... 9.999 Hz (automatic software filter at 100 Hz/5 ms)
0 ... 99.99 Hz (automatic software filter at 500 Hz/5 ms)
0 ... 999.9 Hz
0 ... 9999 Hz (approximately 10 kHz)
[☼]
no
2
500
Description
No evaluation of the pulse length.
2 Hz with a pulse-duty factor of 1:1 (minimum pulse length 250 ms)
5 Hz with a pulse-duty factor of 1:1 (minimum pulse length 100 ms)
10 Hz with a pulse-duty factor of 1:1 (minimum pulse length 50 ms)
20 Hz with a pulse-duty factor of 1:1 (minimum pulse length 25 ms)
50 Hz with a pulse-duty factor of 1:1 (minimum pulse length 10 ms)
100 Hz with a pulse-duty factor of 1:1 (minimum pulse length 5 ms)
500 Hz with a pulse-duty factor of 1:1 (minimum pulse length 1 ms)
[▲]
[▼]
[▲]
[▼]
EN
33

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis