Herunterladen Inhalt Inhalt Diese Seite drucken

Memorization Procedure - tau D749MA-R Installationsanleitung

Vorschau ausblenden Andere Handbücher für D749MA-R:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 25
9-10-11
Automation type selection
Dip 9
Dip 10
Off
Off
On
Off
Off
On
On
On
Off
Off
On
Off
Off
On
On
On
IMPORTANT: In case the automation type change, a new setting of the dips # 9, 10 and
11 will be required. Before the new setup, however, it is necessary to proceed to a HARD
RESET (see page 24) of the controller.
12
SENSITIVE EDGE

6. MEMORIZATION PROCEDURE

WARNING: After powering the control panel, wait 2 seconds before you start performing the
adjustment operations.
Note: the mechanical stops of the automation must be regulated both in opening and in closing
[see motor instructions].
When you have completed the installation procedures:
Check the position of dip-switches 9, 10 and 11. Dip-switches must be set according to
the automation model (see table of dip-switches 9-10-11, "Logic adjustments" section).
It is recommended to start the learning process with the gate at 0,5 m from closing mechanical stop.
Press without releasing the PROG button till the DL8 LED starts flashing (yellow):
-
the automation starts to open slowly looking for the opening limit gate stop;
If the automation closes instead of opening, stop the run of the gate (by cutting the
photocells or closing the STOP contact), invert the polarity of the motor that closes, take
the gate in the closed position (on the mechanical stop) and restart the procedure from
the beginning.
Note: if the automation does not work, check the input connections. The DL6, DL5, DL4 and
DL3 green LEDS must be on.
-
once the limit gate stop is reached, the automation starts closing looking for the closing limit gate
stop (in this phase the control unit gathers all the parameters regarding the run);
-
the automation carries out one complete opening to optimize the opening power;
-
after a short pause, the automation carries out one complete closure to optimize the closing power.
WARNING:
-
The procedure can be stopped by pressing the STOP button.
-
During the various stages of the operation, if the sensor is activated saving is stopped. To
restart the procedure from the beginning (with the DL8 yellow LED flashing), use the AP/CH
control, the remote control (if programmed) or press the PROG button briefly.
Please remember that an obstacle during saving is interpreted as a mechanical limit stop
(the system does not start any safety operation, it just stops the motors).
Make sure you don't stand near the automation during saving.
7. D749MA-R CHARACTERISTICS
Dip 11
Automation
Off
ARM up to 200 Kg or leaf less than 3 m.; EASY12QR; ZIP12
Off
ARM more than 200 Kg or leaf greater than 3 m.
Off
R18
Off
R40
On
B12ENC, BIUNO-BT
On
not used
On
not used
On
not used
On
RESISTIVE SENSITIVE EDGE (terminal No. 10).
FIXED EDGE (NC contact – terminal No. 10).
Off
Note: if not used, keep the DIP in the OFF position.
19

Werbung

Inhaltsverzeichnis
loading