ROLLING CODE MODE
It is possible to activate or disable the ROLLING CODE mode. Its
activation makes any attempt of code duplication impossible.
To activate the "ROLLING CODE" function it is necessary to act
on the Dip-switch 2 on the printed circuit:
Dip 2 ON = ROLLING CODE mode activated
Dip 2 OFF = ROLLING CODE mode not activated
Enabling the ROLLING CODE by means of WINPPCL makes the
Dip-switch 2 position ineffective.
REMOTE RADIO LEARNING
This procedure allows to memorize new transmitters by radio, in
sequence and without removing the receiver from the
installation.
The transmitter which allows to enable the programming by
radio must be memorized in advance.
All transmitters programmed by radio will share the same key
configuration as the transmitter which activated the
programming.
Example:
TX A transmitter memorized with the following key configuration:
Key 1 on the first channel in monostable mode.
Key 2 on the third channel in timer mode.
Key 3 on the fourth channel in bistable mode.
TX B transmitter to memorize.
Hold for 5 seconds minimum the keys 1+2 or 1+3 of TX A
Release both keys
Press, within 5 seconds, the required key of TX B
Release and press within 5 seconds on the TX B another key
to be memorized. Repeat this operation for other transmitters
To exit the self-learning mode wait for at least 5 seconds
The key configuration of TX B transmitter and other
transmitters, set with this procedure, will be the same as
TX A transmitter.
SUBSITUTIVE TRANSMITTER
The substitutive transmitter, generated only by means of
WINPPCL, allows to replace by radio a transmitter stored in the
receiver.
A single transmition with the specially programmed
SUBSTITUTIVE TX, nearby the receiver, replaces the transmitter
code with the new one without removing the receiver from the
installation.
To synchronise the ROLLING CODE transmit twice with each key
of the SUBSTITUTIVE TX.
Example:
Memorized TX A transmitter
It is possible to make three replacements maximum per code, so
for TX A you can find:
TX B replaces TX A (TX A is no longer operative)
TX C replaces TX B (TX B is no longer operative)
TX D replaces TX C (TX C is no longer operative)
FULL CODE ERASING
To perform a full code erasing do the following:
Turn off the power of the receiver
Press and hold pressed the SW1 key of the receiver
At the same time turn on the power again. The receiver LED
goes on: release the SW1 key
The memory spaces are empty and available for a new
programming.
To perform a partial code erasing the PROG2 portable
programmer is required.
PROGRAMMING LOCK
La funzione di BLOCCO PROGRAMMAZIONE è impostabile solo
tramite WINPPCL.
Questa funzione impedisce una qualsiasi riprogrammazione del
ricevitore, sia tramite il tasto SW1 che via radio. Il ricevitore può
essere riprogrammato solo tramite WINPPCL.
RELAY CONTACT
The four output relay contacts are normally open type; it is
possible to change it as normally closed type. Refering to fig. 1
connect point A with point B and cut the trace at point C (Fig.1).
WARNING! IF THE RECEIVER IS SUPPLIED BY 24 VAC-VDC,
DO NOT ACTIVE MORE THAN 2 RELAYS SIMULTANEOUSLY

TECHNICAL DATA

Power supply
12 Vac/dc (DIP 1 ON) / 24 Vac/dc (DIP 1 OFF)
Relay contacts
1A / 30Vdc
Temperature
-20 ÷ +60°C
Consumption
17mA stand by
Sensibility
≥ -103 dBm
S/N
> 17dB @ 100dBm m=100%
Size
132 x 26 x 74 mm
Protection degree IP55
IMPORTANT REMARKS
"This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation."
"Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to
operate the equipment."
99/05/CE DIRECTIVE CONFORMITY
The WALLY are in conformity with the provisions of the following
EC directive(s) (including all applicable amendments) and that the
standards referenced here below:
EN 60950-1, EN 301 489-1, EN 301 489-3, EN 300 220-3
Racconigi, 12/01/2010
V2 SPA legal representative
Cosimo De Falco