IMPORTANT REMARKS

For technical information or any installation problem, you can call
our customer service during office hours
TEL. (+39) 01 72 81 24 11
V2 S.p.A. has the right to modify the product without
previous notice; it also declines any responsibility to
damage or injury to people or things caused by improper
use or wrong installation.
Please read this instruction manual very carefully
before installing and programming your devoce..
This instruction manual is only for qualified technicians, who
specialize in installations.
Every programming and/or every maintenance service should
be done only by qualified technicians.
The installer should make arrangements for installation of an
automatic protection device and a fuse.
The standards require a breaker spacing of at least 3 mm for
each pole (EN 60335-1).
The automatic breaker should guarantee omnipolar system
power isolation.
The protection device trip current should not exceed 8A.
The connection cables should be suitable for installation in
wet outdoor environments
It is essential to use cables of the proper size for the cable
duct used to guarantee a protection level of IP55 for the
casing.

DECLARATION OF CONFORMITY

V2 SpA hereby declares that the products:
WALLY2-230V, WALLY2-120V
comply with the following directives:
99/05/CEE
radio
2006/95/CEE
electrical safety
2004/108/CE
electromagnetic compatibility
To verify compliance, the following technical standards
have been applied:
EN 60335-1, EN 55014-1, EN 55014-2, EN 301 489-1,
EN 301 489-3, EN 300 220 - 3
Racconigi, 29/07/2010
V2 S.p.A. legal representative
Cosimo De Falco

TECHNICAL DATA

Alimentation
Relay contact
Nominal Frequency
Working temperature
Consumption
Sensibility
S/N
Size
Weight
Protection
230V dual channel receiver, capable to
control loads up to 1500W
Operates with Royal or Personal Pass series transmitters:
the first remote control to be memorised determines the
mode of operation; Royal or Personal Pass.
The Personal Pass version allows up to 240 different remote
controls to be memorised.
Monostable, bistable or timer operating logoc.
Basic programming using button SW1 or advanced
programming using the PROG2 programming device and
WINPPCL software
PROGRAMMING
The self learning programming system enables the code
memorization and the setting of the following functioning
modes:
MONOSTABLE: it activates the corresponding relay through the
time of TX transmission. When the transmission stops, the relay
goes automatically off.
BISTABLE: it activates the corresponding relay on the first TX
transmission. The relay goes off on the second transmission.
TIMER: the tx transmission activates the corresponding relay
which goes off after the set time (max 7,5 minutes).
NOTE: the first remote control to be memorised determines
the mode of operation; Royal or Personal Pass.
To change the operating mode, it is essential to perform a
COMPLETE CANCELLATION and then memorise the new
remote control.
IMPORTANT: to memorize the code in the correct way
it is necessary to keep a minimum distance of 1,5 metres
between the transmitter and the receiver's antenna.
7
230V models
120V models
230Vac - 50Hz
120Vac - 60Hz
10A / 250Vac
10A / 120Vac
433,92 - 868,30 Mhz
-20 ÷ +60 °C
20 mA standby
≥ -103 dBm
> 17dB @ 100dBm m=100%
113 x 113 x 57 mm
200g
IP55