1) CONTROL PANEL CP.BULL5 ARC
The radio receiver in this product is compatible only with ARC (Advanced Rolling Code) transmitters which, thanks to 128 bit
coding, guarantee superior anti-copying security.

1.1) WIRE DIAGRAM

Wire connections shown in Fig. 1 are described hereunder:
Terminals
Function
Power
L-N-GND
supply
MOT-COM-MOT Motor
N-BLINK
LAMP
SWO
SWO
SWC
SWC
PHOT (CLOSE)
PHOT
STOP
STOP
COM
COM
Step
P.P. (OPEN)
by-Step
24 VAC
24Vac
SCA
SCA
ENC1
ENCODER
SHIELD-ANT
Antenna
Note: The control unit uses a "P2" key with the same functions of the Step-by-Step push-button. This is useful to control the automatic
system during installation (only with DIP2: OFF).

2) CHECKING CONNECTIONS

1) Cut off power supply.
2) Manually release the door, move it at around half stroke and lock it again.
3) Reset power supply.
4) Send the step-by-step (P.P.) control signal through the P2 key, P.P. or remote control.
5) The door leaves should open. If not, with stopped motor, it is sufficient to invert the move wires of the motor (MOT/MOT) of the
motor and the limit switches (SWO/SWC).
6) Proceed with regulations described in "STROKE ACQUISITION & SLOWDOWNS"
3) TRIMMER FUNCTIONS
3.1) TW - If the Encoder device is installed, it assumes the function of regulating anti-crushing sensitivity. When turned in a clockwise
direction, sensitivity is increased.
In the absence of an Encoder device, regulate the maximum duration of opening and closing manoeuvres. It must be preset approx. 4s
more with respect to the actual stroke time of the system. The adjustment ranges from 3s to 180s maximum. If the stroke acquisition
and slowdowns procedure is executed, the position of the trimmer has no effect on the operation time.
3.2) TCA - It allows to adjust the automatic closure time.The adjustment ranges from 3s to 180s maximum.
With TCA trimmer completely turned clockwise, the DL2 LED (green) switches off, TCA is deactivated.
ARC TRANSMITTERS
IMPORTANT, PLEASE READ CAREFULLY:
Description
Input, 230VAC 50Hz (CP.BULL5 ARC)
Input, 115VAC 50/60Hz (CP.BULL5 ARC 115V))
(1-Phase/2-Neutral/GND-Ground connection)
Connection to motor: (MOT-move/COM-Common/MOT-move)
Output, connection to Flashing light
CP.BULL5 ARC: 230 Vac 40W max.
CP.BULL5 ARC 115V: 115 Vac 40W max.
Input, OPENING limit switch (Normally Closed contact)
Input, CLOSING limit switch (Normally Closed contact)
Input, connection to safety devices, Normally Closed (N.C.) contact (e.g. photocells): configurable through DIP3).
In "Service man" mode, it activates the CLOSE function.
In this case connect a Normally Open (N.O.) key.
Input, STOP key (N.C. contact)
Can assume the Close or Pedestrian function (contact N.O.) see "Advanced Programming" paragraph.
Common, all control inputs.
Input, step-by-step key (N.O. contact). Can assume the OPEN function see paragraph "Advanced Programming".
In "Service man" mode, it activates the OPEN control function.
Output, 24Vac/200mA max accessory power supply.
Contact free from voltage, not insulated for the connection of open gate indicator lamp. Open contact with
closed door leaf. Flashing light during the door leaf movement. With open door leaf, the contact is closed.
Input, connection of the encoder (OPTIONAL). See section 5
Connection of the antenna to the incorporated radio-receiver module (SHIELD-screen/ANT-signal).