5.0 Edit parameters
Press ESC for 2 seconds (until the beep) to access the edit parameter mode.
Use ESC to scroll through the parameters, use P1 and P2 to edit them.
Press OK for 2 seconds (until the beep) to save the current value.
Press ESC again for 2 seconds (until the beep) to quit the edit mode.
N
Def.
Min.
1
70
2
40
3
4
4
3
5
5
6
4
7
50
8
38
9
12
A
2
B
75
C
0
D
0
E
0
F
0
G
0
H
1
J
8
LBT0428 DS42502-003Elektronik
Rev. 04
Max.
Parameter
Opening speed
Closing speed
Opening slowdown speed
Closing slowdown speed
Opening braking
Closing braking
Opening approaching space
Closing approaching space
Force against obstacle
Pause time
% of partial opening stroke
Electric lock type
Traffic adaptation
If door is forced
With blackout
With low battery
Motion direction () (Facing door from the
outside)
Voltage with door closed (windproof)
WK120
ESC
S. 46 | 76
P1
P2
Notes
In mm/second
In mm/second
In mm/second
In mm/second
Absolute value
Absolute value
Absolute value
Absolute value
Absolute value
In seconds
Partial opening is active with RADARS and
OPEN, but not with START command.
0=Monostable
1=Bistable
0=Not enabled 1=Enabled
0=It resists to forcing
1=It opens
2=It stays free
0=It continues operation
1=It opens although in lock mode
2=It closes and locks
3=It opens only if not in lock mode
4=It closes but does not lock
0=It opens to the left 1=It opens to the right
Absolute value
fig.6
OK