Connection cover for magnetostrictive linear position sensor
4
Assembly, disassembly and connection (continued)
4.3

Equipment parts

If the BTL or connection housing is left individually or
disassembled in the plant, note the following:
Leave connection terminal without power!
Use cable shield to ground the BTL through the ground
terminal or connection housing.
Use original equipment protection caps to protect from
contamination.
Use additional securing of the protection caps
depending on the installation mounting position,
vibration, temperature etc.
Protect any components and the protection cap left in
the plant from mechanical stress and damage.
4.4

Electrical Connection

The electrical connection is permanent and made using a
cable. For the connection assignments, see Tab. 4-1.
DANGER
Explosions
Connecting the BTL in an explosion hazard atmosphere
could result in explosions. This could result in personal
injury and equipment damage.
► Connect only in non-EX zone areas or in a suitable
enclosure.
Note the information on shielding and cable
routing (see Section 4.5).
www.balluff.com
Wire color
Signal
Brown
BN
10...30 V
Blue
BU
GND
Green
GN
RxD/TxD-N (A) IN
Red
RD
RxD/TxD-P (B) IN
Black
BK
RxD/TxD-N (A) OUT
White
WH RxD/TxD-P (B) OUT
Pink
PK
+5 V OUT
Gray
GY
DGND OUT
Transparent
Shield
Tab. 4-1:
Pin Assignments
The power consumption of the BTL must be
limited externally by the user to 4 W!
Bus termination
If the BTL is the last slave in the PROFIBUS line, an active
bus terminator must be installed (see Fig. 4-1).
+5 V OUT
RxD/TxD-P (B) OUT
RxD/TxD-N (A) OUT
DGND OUT
Fig. 4-1:
Bus termination
If the device is installed in the middle of the PROFIBUS
line, +5 V OUT and DGND OUT are not connected. Be
sure however to isolate with respect to ground and other
signals.
Connection
BTL on power
supply
BTL on
PROFIBUS line
Next PROFIBUS
slave or active
PROFIBUS
termination
resistor
Active
PROFIBUS
termination
resistor
390
220
390
english
9