DRAIN REQUIREMENTS continued
Drain Adapter (Figure 7)
A drain adapter is provided to accommodate 3/8" tubing drain
line material.
On tube or hose drain line, use a hose clamp to secure drain line
to barbed fitting Also, select a firm hose that will not soften and
collapse or kink at high temperature, at suspension points or at
sharp bends. Plumbing codes do not permit a direct connection
into any sanitary or storm drain. An air gap of at least 2" is usually
required so sewer backup will not contaminate the system.
Clamp the drain line securely to a rigid surface to prevent it from
moving during regeneration. Entire drain system must be able
to handle maximum regeneration flow of 5 GPM. Drain should
not be elevated more than five (5) feet above the control valve. If
conditions mandate that the drain must be higher, see discussion
of special drain situations below.
INCORRECT
Construct air gap as shown or purchase air gap
device as used with clothes washers.
Figure 7
Special Drain Line Situations
On some installations it may be necessary to have the drain line
rise more than five (5) feet above the control valve. Explained
below are special modification for improving performance under
these adverse conditions.
Figure 8
In cases where drain line empties into an "overhead" sewer line,
a "sink" type trap must be used. Do not connect or seal drain line
to trap. Secure drain line to provide an air gap or use an air gap
device.
Valve Drain Line to
Overhead Sewer
Sewer Line
Valve Drain Line
Figure 8

SYSTEM START-UP

Setting the Timer - Typical Residential Application
To program, set the time, set the hardness and the meter
automatically monitors system needs and regenerates only when
necessary.
NOTE: During shipping the cable from the back of the timer
to the meter assembly may have been disconnected.
If it has, insert the end of the cable into the top of the
meter assembly.
PROGRAMMING
CORRECT
2" AIR GAP
Manual Regeneration
Quick Cycling the Control
Trap
Funnel
Drain or
Air Gap
Device
Time of Day: Press
until desired hour appears. Release.
Range: 0 through 23 hours
0
Note: The elapsed minutes will reset to zero when the hours
are changed.
Regenerant Dosage: Press
dosage appears. Release.
Range: .20 kg to 6.0 kg
0. 6
.20 kg to 1.0 kg by increments of .05 kg
1.0 kg to 3.0 kg by increments of 0.1 kg
3.0 kg to 6.0 kg by increments of 0.5 kg
Capacity Cubic Meters: Press
appears. Release.
Range: 0.40 to 9.5 cubic meters
3.6
0.4 m
3
to 1.0 m
3
by increments of 0.05 m
1.0 m
3
to 3.0 m
3
by increments of 0.1 m
3.0 m
3
to 5.0 m
3
by increments of 0.2 m
5.0 m
to 9.5 m
by increments of 0.05 m
3
3
PROGRAMMING IS COMPLETE
Delayed Regeneration: Press and release
a delayed regeneration. The system will regenerate at the
12
next Time of Regeneration (2:00). Repeat procedure to
disable the Delayed Regen. Regen dot blinks when delayed
regeneration is on.
Immediate Regeneration: Press and hold the
to initiate an immediate regeneration. The control will display a
cascading symbol (- -) as it cycles to backwash. The control will
proceed through a complete regeneration.
Quick Cycling: Press and hold
an immediate regeneration. The control will cycle to the back-
C1
wash cycle.
1.
Press and release the
2.
Simultaneously press then release
the control to the next cycle.
3.
Press and release the
4.
Repeat steps 2 and 3 to cycle through each position.
Quick Cycle to Service Position: Simultaneously press
and hold for 3 seconds during any regeneration cycle. The
control will skip the remaining regeneration cycles and return
to the service position. The Time of Day will be displayed when
the control reaches the service position.
Sys-man-Riv A AP12 • 5
until desired regenerant
EN
until desired interval
3
(12 increments)
3
(20 increments)
3
(10 increments)
(10 increments)
3
to program
for 3 seconds
for three seconds to initiate
to display "C 1"
and
to move
to display "C 2"
and