Herunterladen Inhalt Inhalt Diese Seite drucken

Softener Specifications; General Precautions; Proper Order To Install Water Treating Equipment - Pentair RIVERSOFT serie Montage- Und Bedienungsanleitung

Mengengesteuerter wasserenthärter
Vorschau ausblenden Andere Handbücher für RIVERSOFT serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 27

SOFTENER SPECIFICATIONS

Characteristics
Resin liters (l)
Nominal flow rate (m³/h)*
Peak flow rate (m³/h)*
Exchange capacity (°f/m³)
Salt consumption per regeneration (kg)
Water consumption per regeneration (l)**
Salt storage (kg)
Width (cm)
Depth (cm)
Height (cm)
Approx. ship weight (kg)
Power requirements
EN
Water pressure range
Water temperature range
Inlet/Outlet connections
Note: All the calculations are based on salt dosage setting of 120g/liters.
*Indicatives data. Maximum flow rate to produce in order to respect the required service velocity for an optimal
ion exchange, independently from the inlet pressure.
** Values may vary upon local condition and programming. Consumption for RiverSoft 4 and RiverSoft 8 are
given for system u3 programmed. Consumption for RiverSoft 16 and RiverSoft 25 are given for a system u4
programmed.
All consumptions are given for an inlet pressure of 3.44 bar (50 Psi).

GENERAL PRECAUTIONS

Before you begin installation, read the entire manual. Gather all
materials and tools needed. Improper installation voids warranty.
Do not use with water that is microbiologically
WARNING:
unsafe or of unknown quality without adequate
disinfection before or after the softener.
SODIUM INFORMATION: Water softeners
WARNING:
using sodium chloride for regeneration will
add sodium to the water. Persons who are on
sodium-restricted diets should consider the
added sodium as part of their overall sodium
intake.
NOTE: Sodium Chloride or Potassium Chloride are
recommended.
NOTE: The efficiency of this softener shall be valid only at
the stated salt dosage.
RECOMMENDATION: a qualified plumber should be contracted
to make all difficult piping installations.
Softener must be protected against freezing,
CAUTION:
which can cause cracking of the softener and water
leakage.
Do not treat water over 43°C because hot water will
CAUTION:
damage the softener and void warranty.
Locate the softener within 500 cm of drain.
CAUTION:
Drain must be capable of handling a maximum
backwash flow rate of 19 liters of water per minute.
Maximum allowable inlet water pressure is
CAUTION:
8 Bars if daytime pressure is around 8 Bars,
nighttime pressure may exceed the maximum.
Use a pressure-reducing valve if necessary. Use a
pressure-reducing valve if necessary.
NOTE:
Handle softener with care. Do not turn upside
down, drop, or set on sharp objects.
2 • Sys-man-Riv A AP12
RiverSoft 4
RiverSoft 8 RiverSoft 16 RiverSoft 25
3,5
8
16
0,21
0,48
0,96
0,28
0,64
1,28
21,00
48,10
96,30
0,42
0,96
1,92
26
47
117
6
25
50
17,8
31
31
35,7
43,5
43,5
43,5
68
113,5
5
10
16
220 VAC 50/60 Hz
1.5 to 8 Bars
2 to 38 C°
3/4 inch – BSPT, male
NOTE: The valve requires a minimum inlet pressure of 2 bars
at 1.2m
.
3
NOTE: If you are on a private well system, check minimum
water pressure with an accurate gauge. (Gauges on
25
older water systems are often inaccurate). Pressure
1,50
2,00
that is less than 30 psi may cause low flow rate and
150,30
inadequate regeneration.
3
When connecting your unit, take note that the
CAUTION:
123
inlet, outlet, and drain connections are made in
50
accordance with state and local plumbing codes.
31
43,5
Do not over-tighten pipe to piping boss.
CAUTION:
113,5
Due to some homes using piping as a source of
27
CAUTION:
electrical grounding, a grounding strap must be
installed where required.
Do not heat piping if it is in contact with the
CAUTION:
control valve.
NOTE: Do not put excessive force on the inlet/outlet drain
connections of the control valve.
NOTE: Do not use pipe joint compound or plumber's putty
when threading pipe into the piping boss. Use only
Teflon® Tape.
Do not use any chemical substance (out off
WARNING:
suggested in Pg. 6) to clean resin or softener
component with out the approval of the
producer
Electrical Precautions
The unit must be plugged into an outlet.
WARNING:
Do not use any extension cords.
WARNING:
Locate cord where it cannot be accidentally
WARNING:
unplugged or cause any bodily harm.
Electrical components are not waterproof.
WARNING:
Make sure power source matches the rating on the
CAUTION:
unit.
Make certain the electrical supply cannot be
CAUTION:
turned off accidentally.
NOTE: The outlet you select must not be controlled by a wall
switch.