Herunterladen Inhalt Inhalt Diese Seite drucken

Removing From The Ceiling Bracket; Operation; Function Test - HomeMatic HmIP SWSD Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operation

5.3.1

Removing from the ceiling bracket

If you want to remove the device from the ceiling bracket,
please press the release lever and turn the device out of
the ceiling bracket (see figure 6).
6
Operation
After latching and teaching-in the device, simple operat-
ing functions are available directly on the device:
• Press the operating button (D) one time briefly
(< 4 s) to trigger the function test of the smoke
alarm.
• Press and hold down the operating button (D)
one time for longer than 4 s to trigger the com-
munication test with other connected smoke
alarms.
6.1

Function test

If you have installed and taught-in the smoke alarm suc-
cessfully, you have to perform a function test first. It is
also recommended to perform a function test once a
month after installation to ensure correct operation of
the device.
To perform the function test, proceed as follows:
• Press the operating button (D) of the device one
52

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Hmip-swsd

Inhaltsverzeichnis