Herunterladen Inhalt Inhalt Diese Seite drucken

WIKA NG 63 Betriebsanleitung Seite 18

Manometer mit reed-kontakt typ 851-a, für explosionsgefährdete bereiche
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5. Commissioning, operation
When screwing the instruments in, the force required for sealing
must not be applied through the case, but only through the
spanner flats provided for this purpose, and using a suitable tool.
EN
For parallel threads, use flat gaskets, lens-type sealing rings or
WIKA profile sealings at the sealing face
(e.g. NPT threads), sealing is made in the threads
suitable sealing material (EN 837-2).
The torque depends on the sealing used. In order to orientate the
measuring instrument so that it can be read as well as possible, a
connection with LH-RH union or union nut should be used. When
a blow-out device is fitted to an instrument, it must be protected
against being blocked by debris and dirt.
Sealing face
Installation
Nominal position per EN 837-3 / 9.6.6 figure 7: 90° ( ⊥ )
Process connection lower mount
18
Spanner flats
Pressure gauge with reed contact model 851-A, for Ex areas
Installation with open-ended
spanner
. With tapered threads
Sealing in the
thread
, using a