Temperaturschalter
Vorschau ausblenden Andere Handbücher für TSM 125:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

MENU STEP N2 – SWITCH OFF
Off
25.1
Identified by the OFF. Here you can select the temperature at which an external
device should be switched OFF. The value can be selected with the buttons
pq in 0,1°C increments. The selection is confirmed by pressing SET and the
display will switch to the next step.
Settings range: -55,0°C...+125,0°C
MENU STEP N3 – TURN-ON DELAY
dL
2,0
Identified by the dL. This step will show you the turn-on delay of the relay. The
value can be selected by pressing pq. The selection is confirmed by pressing
SET and the display will switch to the next step.
This setting is useful if ON and OFF switching temperature are very close to-
gether. Setting a turn-on delay avoids too frequent switching of only slightly
changing temperatures. Settings range: 0...999.9 seconds
MENU STEP N4 – HIGHEST MEASURED TEMPERATURE
Hi
25,1
Identified by the Hi. This step will show you the highest measured temperature.
The value can be deleted by pressing pq. The selection is confirmed by pres-
sing SET and the display will switch to the next step.