MAINTENANCE

WARNING:
Always use a P2-respirator during performing
maintenance.
Never reuse the air filter after removal of the
machine.
CAUTION:
Always be sure that the tool is switched off and
unplugged before attempting to perform inspection
or maintenance.
Never use gasoline, benzine, thinner, alcohol or the
like. Discoloration, deformation or cracks may result.
Please check with your local authorities for any
regulations regarding the use of these vacuum
cleaners when working with toxic materials such
as Asbestos.
Before any repair or maintenance always check
what materials the vacuum cleaner has been
working
with.
professionally cleaned by licensed asbestos / toxic
cleaning company before conducting any repair or
maintenance.
A technical inspection, including inspection of
filters, air tightness, and control mechanism, must
be performed
by an instructed person at least
once a year, or more frequently as may be
specified by national requirements.
During maintenance, all contaminated items which
cannot be satisfactorily cleaned must be disposed.
Such items must be disposed of in impervious
hags which accord with your country's regulations.
After the operation in the hazardous area, the
outside of the tool must be decontaminated by
vacuum cleaning methods and wiped clean or
treated with sealant before you take the tool out of
a hazardous area. All the parts of the tool must be
regarded as contaminated when removed from the
hazardous area, and appropriate action must be
taken to prevent dust dispersal.
Change the air filter when the air filter is clogged
with
dust
or
performance declined.
Check the filters periodically. If there is a tear on it,
replace it immediately.
Removing the air filter
CAUTION:
Wait for about 5 minutes so that dust in the tank
completely settles down.
Make sure that the tool is unplugged.
Be careful not to let the dust enter inside the tank
cover when removing the air filter.
Fig.16
Unhook the tank cover and remove it carefully. Put it up
side down.
If
in
doubt,
always
you
feel
that
the
Fig.17
Remove the screw on the stopper lever.
Unlock the filter hooks by flipping the stopper lever.
Fig.18
Cover the air filters with a plastic bag.
Fig.19
Remove the air filters from the tank cover carefully and
tie the plastic bag firmly.
Assembling the air filter
When you get the air filter components separately,
assemble them as follows.
Fig.20
Put the prefilter over the powder filter.
Fig.21
Make sure that the borders of prefilter and powder filter
are set properly.
Installing the air filter
have
Fig.22
Wipe off the seal face.
Set the new air filters and fix them with the filter hooks.
Flip the stopper lever to lock the air filters.
Lock the filter hooks with the screws.
Set the tank cover onto the tank and lock it with hooks.
Fig.23
NOTICE:
Make sure the hooks on the filters are set at the
correct position.
Cleaning the level sensors
Fig.24
The level sensors detect liquid when the tank becomes
full with liquid. Clean the level sensors with a soft cloth
from time to time when changing the air filters.
Storage of power supply cord
Fig.25
Fig.26
Wind up the power supply cord around the multi-hook or
the base hook.
cleaner's
Storage of accessories
NOTE:
Do
accessories that are held by the pipe holder.
Applying an excessive force to these accessories
may cause damage to the pipe holder.
Fig.27
Pipe rest can be used to store straight pipe, bent pipe
and others by just inserting these accessories.
Fig.28
The pipes can be placed into the pipe holder when also
stopping using the cleaner on the way for a while.