Herunterladen Inhalt Inhalt Diese Seite drucken

Faults And Damages; Ex-Relevant Safety Regulations - i.safe MOBILE IS-MP.2 Schnellstartanleitung

Vorschau ausblenden Andere Handbücher für IS-MP.2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

FAULTS AND DAMAGES

If there is any reason to suspect that the safety of the device has been compromised, it
must be withdrawn from use and removed from any ex-hazardous areas immediately.
Measures must be taken to prevent any accidental restarting of the device.
The safety of the device may be compromised, if, for example:
Malfunctions occur.
The housing of the device shows damage.
The device has been subjected to excessive loads.
The device has been stored improperly.
Markings or labels on the device are illegible.
It is recommended that a device which shows or which is suspected of faults and da-
mages is returned i.safe MOBILE GmbH for inspection.

EX-RELEVANT SAFETY REGULATIONS

Use of this device assumes that the operator observes the conventional safety
regulations and has read and understood manual, safety instructions and certificate.
The following safety regulations must also be complied with:
Inside ex-hazardous areas the cover of the USB interface has to be closed.
To ensure the IP protection, it has to be ensured that all gaskets are present and
functional. There must be no large gap between the two halves of the housing.
The battery may only be charged outside ex-hazardous areas using the appropriate
charger or other equipment approved by i.safe MOBILE GmbH.
The device may be charged only at temperatures in between 5 °C ... 35 °C.
The device must not be exposed to abrasive acids or bases.
The device must not be taken into zones 0, 1, 20 or 21.
Only accessories approved by i.safe MOBILE GmbH may be used.
EX-RELEVANT SAFETY REGULATIONS FOR NORTH AMERICA
Conditions of Acceptability:
The device shall be charged only outside ex-hazardous areas. A corresponding
warning is placed onto the label.
The battery pack is placed permanently into the housing. It is not user-serviceable.
Mini USB charge and data connector is protected by plug against dust and may not be
used in hazardous areas.
EN
5

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis