  • Seite 1 SIT SE 144 -1 331251 Byte av cirkulationspump Byte av cirkulationspump SPLIT SERVICEINSTRUKTION - Byte av cirkulationspump ECO PWM10 SERVICE INSTRUCTIONS - Replacement of the circulation pump ECO PWM10 WARTUNGSINSTRUKTIONEN - Wechsel des Umwälzpumpensatzes ECO PWM10...
  • Seite 3 SERVICEINSTRUKTION Byte av cirkulationspump Allmänt Denna serviceinstruktion beskriver byte av cirkulations- pump E6 PWM7/ECO PWM10 i SPLIT innedelar. Se instruktion för byte i kompaktinnedel, Hydro Unit, på sidan 4. Se instruktion för byte i Hydro Box på sidan 11. Läs igenom hela instruktionen innan arbetet påbörjas.
  • Seite 4 VARNING! Byte av cirkulationspump i kom- Gör aggregatet spänningslöst innan arbetet påbörjas. paktinnedel (Hydro Unit) Elistallation samt service ska ske under överinseende av behörig elinstallatör. Demontering av luckor Byte av cirkulationspump...
  • Seite 5 OBS! Demontering Stäng inkommande ledning XL2. Släpp ut trycket via OBS! säkerhetsventilen. Ställdon QM31 ska vara i stängt Var aktsam vid demontering och notera kabeldrag- läge. ningar samt kontakters placering. Stäng av klimatsystemet genom att stänga avstängningsventilen (QM31) och ventilen vid partikelfiltret (HQ1). QM31 Släpp ut trycket via avluftningsventilen (QM20) och lämna den öppen.
  • Seite 6 Frånkoppla strömkabeln på terminal XJ1. Frånkoppla PWM-signalkabeln från terminal X1:1 och X1:2 på kommunika- tionskortet (AA23). X1:1 X1:2 Demontera cirkulationspumpen, börja med den nedre röranslutningen. Byte av cirkulationspump...
  • Seite 7 Utan energimätare: Lossa den övre muttern (A) och avlägsna röret genom att att lossa de två röranslutningspunk- terna (B). Med energimätare: Lossa den övre muttern (A) och avlägsna röret genom att att lossa röranslutningen till flödes- mätaren (C). Avlägsna cirkulationspumpen. Byte av cirkulationspump...
  • Seite 8 OBS! Montering OBS! OBS! På kommunikationskortet (AA23) kopplas blå kabel OBS! (signal) in på X1:1. All elektrisk inkoppling skall ske av behörig elektriker. Svart kabel kopplas in på X1:2. Elektrisk installation och ledningsdragning skall utfö- ras enligt gällande bestämmelser. Byt packningarna, använd de som bifo- gats reservdelspumpen.
  • Seite 9 Öppna försiktigt de stängda ventilerna. Sök efter eventuella vattenläckor. QM31 Kontrollera systemtrycket på manome- tern (BP5). Fyll på systemet med vatten om det behövs. Klimatsystemets säkerhetsventil (FL2) skall vara helt tät. Avlufta systemet via avluftningsventi- lerna (QM20), (QM24) och (QM60). QM24 QM20 QM60...
  • Seite 10 Anslut PWM-kabeln till kommunika- tionskortet (AA23), terminal X1. Blå ledare (PWM) till position 1. Svart ledare (PWM GND) till position Anslut strömkabeln till terminal XJ1. Anslut strömmen och starta upp värme- pumpsystemet. Avlufta igen om det behövs. Kontrolle- ra systemtrycket på manometern (BP5). 13a.
  • Seite 11 Byte av cirklationspump i innedel (Hydro Box) Demontering av luckor VARNING! Gör aggregatet spänningslöst innan arbetet påbörjas. Elistallation samt service ska ske under överinseende av behörig elinstallatör. Byte av cirkulationspump...
  • Seite 12 OBS! Demontering Stäng inkommande ledning XL2. Släpp ut trycket via OBS! säkerhetsventilen. Ställdon QM31 ska vara i stängt Var aktsam vid demontering och notera kabeldrag- läge. ningar samt kontakters placering. Stäng av klimatsystemet genom att stänga avstängningsventilen (QM31) och ventilen vid partikelfiltret (HQ1). (Ventilen vid partikelfiltret (HQ1) är monterad utanför enheten.) QM31...
  • Seite 13 Frånkoppla strömkabeln på terminal XJ1 (dold i bilden). Följ kabeln från pumpen för att hitta XJ1. XJ:1 Frånkoppla PWM-signalkabeln från terminal X1:1 och X1:2 på kommunika- tionskortet (AA23). X1:1 X1:2 AA23 Byte av cirkulationspump...
  • Seite 14 Demontera ställmotorerna genom att lossa insexskruven vid ställdonen (QM30), (QM31) och (QN11), för att skapa större arbetsutrymme. QN11 QM30 QM31 Skruva loss cirkulationspumpen (GP1) från rören. Byte av cirkulationspump...
  • Seite 15 Skruva loss röret vid anslutningen till värmeväxlarens (EP2) nedre ingång (A). Lossa röret vid pumpen (B), men behåll det på plats. Avlägsna cirkulationspumpen. Byte av cirkulationspump...
  • Seite 16 OBS! Montering OBS! OBS! På kommunikationskortet (AA23) kopplas blå kabel OBS! (signal) in på X1:1. All elektrisk inkoppling skall ske av behörig elektriker. Svart kabel kopplas in på X1:2. Elektrisk installation och ledningsdragning skall utfö- ras enligt gällande bestämmelser. Använd de medföljande röranslutning- arna och montera dessa på...
  • Seite 17 Montera ställmotorerna till ställdonen (QM30), (QM31) och (QN11). QN11 QM30 QM31 Öppna försiktigt de stängda ventilerna. Sök efter eventuella vattenläckor. Avlufta systemet via avluftningsventi- len (QM20) och stäng därefter avluft- ningsventilen. QM20 Kontrollera systemtrycket på manome- tern (BP5). Fyll på systemet med vatten om det behövs.
  • Seite 18 Isolera alla röranslutningar noga. Byte av cirkulationspump...
  • Seite 19 Förlägg PWM-kabeln på metallplåten mot kommunikationskortet (AA23). (Se pilarna.) Fixera med buntband. Byte av cirkulationspump...
  • Seite 20 Anslut PWM-kabeln till kommunika- tionskortet (AA23), terminal X1. Blå ledare (PWM) till position 1. Svart ledare (PWM GND) till position AA23 Anslut strömkabeln till terminal XJ1 (dold i bilden). XJ1 sitter till vänster om plintraden. XJ:1 Byte av cirkulationspump...
  • Seite 21 Anslut strömmen och starta upp värme- pumpsystemet. Avlufta igen om det behövs. Kontrolle- ra systemtrycket på manometern (BP5). Återmontera luckorna. Byte av cirkulationspump...
  • Seite 22 SERVICE INSTRUCTIONS Replacement of the circulation pump General This service instruction describes the replacement of circu- lation pump E6 PWM7/ECO PWM10 in SPLIT indoor modules. See instructions for replacement in compact indoor section Hydro Unit on page 23. See instructions for replacement in Hydro Box on page 30.
  • Seite 23 WARNING! Replacing circulation pumps in com- Cut the power to the unit before starting work. pact indoor sections (Hydro Unit) Electrical installation and service must be carried out under the supervision of a qualified electrician. Removing the covers Byte av cirkulationspump...
  • Seite 24 NOTE Dismantling Close incoming line XL2 Release the pressure via the NOTE safety valve. Actuator QM31 must be in the closed Take care when removing and make a note of the position. cable routing and positioning of switches. Switch off the climate system by clos- ing the shut-off valve (QM31) and the valve at the particle filter (HQ1).
  • Seite 25 Disconnect the power cable from ter- minal XJ1. Disconnect the PWM-signal cable from terminal X1:1 and X1:2 on the commu- nication card (AA23). X1:1 X1:2 Remove the circulation pump, start with the lower pipe connection. Byte av cirkulationspump...
  • Seite 26 Without energy meter: Slacken off the upper nut (A) and remove the pipe by detaching the two pipe connections points (B). With energy meter: Slacken off the upper nut (A) and remove the pipe by detaching the pipe connection to the flow meter (C).
  • Seite 27 NOTE Mounting NOTE NOTE! On the communication card (AA23) connect the blue NOTE! cable (signal) to X1:1. All electrical connections must be carried out by an Black cable to X1:2. authorised electrician. Electrical installation and wiring must be carried out in accordance with the stipulations in force.
  • Seite 28 Carefully open the closed valves. Look for any water leakage. QM31 Check the system pressure on the manometer (BP5). Fill the system with water if necessary. The climate system safety valve (FL2) must be completely tight. Vent the system via the vent valves (QM20), (QM24) and (QM60).
  • Seite 29 Connect the PWM cable to the commu- nication card (AA23), terminal X1. Blue cable (PWM) to position 1. Black cable (PWM GND) to position Connect the power cable to terminal XJ1. Connect the power and start the heat pump system. Vent again if necessary.
  • Seite 30 Replacing circulation pumps in in- door sections (Hydro Box) Removing the covers WARNING! Cut the power to the unit before starting work. Electrical installation and service must be carried out under the supervision of a qualified electrician. Byte av cirkulationspump...
  • Seite 31 NOTE Dismantling Close incoming line XL2 Release the pressure via the NOTE safety valve. Actuator QM31 must be in the closed Take care when removing and make a note of the position. cable routing and positioning of switches. Switch off the climate system by clos- ing the shut-off valve (QM31) and the valve at the particle filter (HQ1).
  • Seite 32 Disconnect the power cable on termin- al XJ1 (hidden in the image). Follow the cable from the pump to find XJ1. XJ:1 Disconnect the PWM-signal cable from terminal X1:1 and X1:2 on the commu- nication card (AA23). X1:1 X1:2 AA23 Byte av cirkulationspump...
  • Seite 33 Remove the actuator motors by slack- ening off the Allen screws by the actu- ator (QM30), (QM31) and (QN11), to create more working space. QN11 QM30 QM31 Unscrew the circulation pump (GP1) from the pipes. Byte av cirkulationspump...
  • Seite 34 Unscrew the pipe at the connection to the heat exchanger's (EP2) lower input (A). Detach the pipe at the pump (B), but keep it in position. Remove the circulation pump. Byte av cirkulationspump...
  • Seite 35 NOTE Mounting NOTE NOTE! On the communication card (AA23) connect the blue NOTE! cable (signal) to X1:1. All electrical connections must be carried out by an Black cable to X1:2. authorised electrician. Electrical installation and wiring must be carried out in accordance with the stipulations in force.
  • Seite 36 Install the actuator motors for the actu- ators (QM30), (QM31) and (QN11). QN11 QM30 QM31 Carefully open the closed valves. Look for any water leakage. Vent the system via the vent valve (QM20) and then close the vent valve. QM20 Check the system pressure on the manometer (BP5).
  • Seite 37 Insulate all pipe connections properly. Byte av cirkulationspump...
  • Seite 38 Lay the PWM cable on the metal panel against the communication card (AA23). (See the arrows.) Secure using cable ties. Byte av cirkulationspump...
  • Seite 39 Connect the PWM cable to the commu- nication card (AA23), terminal X1. Blue cable (PWM) to position 1. Black cable (PWM GND) to position AA23 Connect the power cable to terminal XJ1 (hidden in the image). XJ1 located to the left of the terminal block row. XJ:1 Byte av cirkulationspump...
  • Seite 40 Connect the power and start the heat pump system. Vent again if necessary. Check the sys- tem pressure on the manometer (BP5). Refit the covers. Byte av cirkulationspump...
  • Seite 41 SERVICEANLEITUNG Wechsel des Umwälzpumpensatzes Allgemeines In dieser Serviceanleitung wird der Wechsel der Umwälz- pumpe E6 PWM7/ECO PWM10 in SPLIT-Inneneinheiten beschrieben. Siehe Anleitung zum Wechsel der Kompaktinneneinheit, Hydro Unit, auf Seite 42. Siehe Anleitung zum Wechsel in Hydro Box auf Seite 50.
  • Seite 42: Abdeckungen Demontieren

    ACHTUNG! Wechsel der Umwälzpumpe in der Unterbrechen Sie vor Beginn der Arbeiten die Span- Kompaktinneneinheit (Hydro Unit) nungszufuhr zum Aggregat. Elektrische Installation sowie Servicearbeiten müssen Abdeckungen demontieren unter Aufsicht eines ausgebildeten Elektroinstallateurs erfolgen. Byte av cirkulationspump...
  • Seite 43 HINWEIS! Demontage Schließen Sie die Eingangsleitung XL2. Lassen Sie den HINWEIS! Druck über das Sicherheitsventil ab. Stellantrieb Gehen Sie bei der Demontage sorgfältig vor und QM31 muss sich in der geschlossenen Stellung befin- protokollieren Sie die Kabelverlegung sowie die den. Kontaktanbringung.
  • Seite 44 Trennen Sie das Netzkabel vom An- schluss XJ1. Lösen Sie das PWM-Signalkabel von Anschluss X1:1 und X1:2 an der Kom- munikationsplatine (AA23). X1:1 X1:2 Demontieren Sie die Umwälzpumpe. Beginnen Sie mit dem unteren Rohran- schluss. Byte av cirkulationspump...
  • Seite 45 Ohne Wärmemengenzähler: Lösen Sie die obere Mutter (A) und entfernen Sie das Rohr, indem Sie die beiden Rohranschlusspunkte (B) lösen. Mit Wärmemengenzähler: Lösen Sie die obere Mutter (A) und entfernen Sie das Rohr, indem Sie den Rohranschluss für den Volumenstrommesser (C) lösen. Entfernen Sie die Umwälzpumpe.
  • Seite 46: Montage

    HINWEIS! Montage HINWEIS! Hinweis: Verbinden Sie an der Kommunikationsplatine (AA23) Hinweis: das blaue Kabel (Signal) mit X1:1. Alle elektrischen Anschlüsse müssen von einem ge- Verbinden Sie das schwarze Kabel mit X1:2. prüften Elektriker ausgeführt werden. Bei der Elektroinstallation und beim Verlegen der Leitungen sind die geltenden Vorschriften zu berück- sichtigen.
  • Seite 47 Öffnen Sie vorsichtig die geschlossenen Ventile. Suchen Sie nach etwaigen Wasserlecks. QM31 Kontrollieren Sie den Systemdruck am Manometer (BP5). Falls erforderlich, befüllen Sie das System mit Wasser. Das Sicherheitsventil des Klimatisie- rungssystems (FL2) muss dicht schlie- ßen. Entlüften Sie das System über die Ent- lüftungsventile (QM20), (QM24) und QM24 (QM60).
  • Seite 48 Verbinden Sie das PWM-Kabel mit der Kommunikationsplatine (AA23), An- schluss X1. Blauer Leiter (PWM) für Position 1. Schwarzer Leiter (PWM GND) für Position 2. Verbinden Sie das Netzkabel mit dem Anschluss XJ1. Schließen Sie die Stromversorgung an und starten Sie das Wärmepumpensys- tem.
  • Seite 49 Bringen Sie die Abdeckungen wieder Byte av cirkulationspump...
  • Seite 50 Wechsel der Umwälzpumpe in der Inneneinheit (Hydro Box) Abdeckungen demontieren ACHTUNG! Unterbrechen Sie vor Beginn der Arbeiten die Span- nungszufuhr zum Aggregat. Elektrische Installation sowie Servicearbeiten müssen unter Aufsicht eines ausgebildeten Elektroinstallateurs erfolgen. Byte av cirkulationspump...
  • Seite 51 HINWEIS! Demontage Schließen Sie die Eingangsleitung XL2. Lassen Sie den HINWEIS! Druck über das Sicherheitsventil ab. Stellantrieb Gehen Sie bei der Demontage sorgfältig vor und QM31 muss sich in der geschlossenen Stellung befin- protokollieren Sie die Kabelverlegung sowie die den. Kontaktanbringung.
  • Seite 52 Trennen Sie das Netzkabel vom An- schluss XJ1 (auf der Abbildung ver- deckt). Folgen Sie dem Kabel von der Pumpe, um XJ1 zu finden. XJ:1 Lösen Sie das PWM-Signalkabel von Anschluss X1:1 und X1:2 an der Kom- munikationsplatine (AA23). X1:1 X1:2 AA23 Byte av cirkulationspump...
  • Seite 53 Demontieren Sie die Stellmotoren durch Lösen der Inbusschraube an den Stellantrieben (QM30), (QM31) und (QN11), um einen größeren Arbeitsbe- reich zu schaffen. QN11 QM30 QM31 Lösen Sie die Umwälzpumpe (GP1) von den Rohren. Byte av cirkulationspump...
  • Seite 54 Lösen Sie das Rohr vom Anschluss für den unteren Eingang (A) des Wärme- tauschers (EP2). Lösen Sie das Rohr an der Pumpe (B), belassen Sie es jedoch an seiner Positi- Entfernen Sie die Umwälzpumpe. Byte av cirkulationspump...
  • Seite 55 HINWEIS! Montage HINWEIS! Hinweis: Verbinden Sie an der Kommunikationsplatine (AA23) Hinweis: das blaue Kabel (Signal) mit X1:1. Alle elektrischen Anschlüsse müssen von einem ge- Verbinden Sie das schwarze Kabel mit X1:2. prüften Elektriker ausgeführt werden. Bei der Elektroinstallation und beim Verlegen der Leitungen sind die geltenden Vorschriften zu berück- sichtigen.
  • Seite 56 Montieren Sie die Stellmotoren für die Stellantriebe (QM30), (QM31) und (QN11). QN11 QM30 QM31 Öffnen Sie vorsichtig die geschlossenen Ventile. Suchen Sie nach etwaigen Wasserlecks. Entlüften Sie das System über das Ent- lüftungsventil (QM20). Schließen Sie danach das Entlüftungsventil. QM20 Kontrollieren Sie den Systemdruck am Manometer (BP5).
  • Seite 57 Isolieren Sie sorgfältig alle Rohran- schlüsse. Byte av cirkulationspump...
  • Seite 58 Verlegen Sie das PWM-Kabel auf der Metallplatte zur Kommunikationsplati- ne (AA23). (Siehe Pfeile.) Nutzen Sie zur Befestigung Kabelbinder. Byte av cirkulationspump...
  • Seite 59 Verbinden Sie das PWM-Kabel mit der Kommunikationsplatine (AA23), An- schluss X1. Blauer Leiter (PWM) für Position 1. Schwarzer Leiter (PWM GND) für Position 2. AA23 Trennen Sie das Netzkabel vom An- schluss XJ1 (auf der Abbildung ver- deckt). XJ1 befindet sich links neben der Klemmenleiste.
  • Seite 60 Schließen Sie die Stromversorgung an und starten Sie das Wärmepumpensys- tem. Führen Sie bei Bedarf eine erneute Entlüftung aus. Kontrollieren Sie den Systemdruck am Manometer (BP5). Bringen Sie die Abdeckungen wieder Byte av cirkulationspump...
  • Seite 64 331251...