Planning the Installation

Recommendation: Create a sketch with working area and all obstacles in order to simplify the installation!
Note: Reinforcement armouring irons in subterranean buildings/adjacent boundary lines and power cables of other
electrical appliances produce magnetic fields that may cause navigation interferences.
Note: Turn off the appliance during long periods of rain. The ground will be muddy after strong rain. The mowing
output may be impaired under such circumstances, and the lawn appearance may suffer.
> 90°
< 0.5 cm
> 35 cm
Max. area: 600m
2
Max. 20°
> 100 cm
24 cm
30 cm
2 cm
> 35 cm
C
User Manual
Distance of the boundary line to the lawn edge
at least 35 cm!
The inner angle of the corners should be above 90°.
Recommendation: 135°! Length at least 40 cm!
135°
The distance between the boundary line
(corridor) and an adjacent boundary line (other
robot) must be at least 1 metre!
With level transitions on terraces / paths, the
boundary wire can be laid close to the edge.
Bypass trees and other obstacles as peninsulas
with the boundary line.
Install the charging station level and near a
power source!
Obstacles, which are shorter than 150mm or not
secured on the ground, shall be encircled with
boundary line as islandes.