Spare parts list

Only use KÄRCHER original battery packs, not non-re-
chargeable batteries.
Description
Battery pack Battery Pow-
er+ 36/75
Battery pack Battery Pow-
er+ 36/60
Battery pack Battery Power
36/50
Quick charger Battery
Power+ 36/60 (EU)
Quick charger Battery
Power+ 36/60 (GB)
Quick charger Battery
Power+ 36/60 (AU)

EU Declaration of Conformity

We hereby declare that the machine described below
complies with the relevant basic safety and health re-
quirements in the EU Directives, both in its basic design
and construction as well as in the version placed in cir-
culation by us. This declaration is invalidated by any
changes made to the machine that are not approved by
us.
Product: Wet/dry vacuum cleaner
Type: 1.528-xxx
Currently applicable EU Directives
2006/42/EC (+2009/127/EC)
2009/125/EC
2011/65/EU
2014/30/EU
Harmonised standards used
EN 50581
EN 55014-1: 2017
EN 55014-2: 2015
EN 60312-1: 2017
EN 60335-1
EN 60335-2-69
EN 61000-3-2: 2014
EN 61000-3-3: 2013
EN 62233: 2008
National standards used
-
The signatories act on behalf of and with the authority of
the company management.
H. Jenner
Chairman of the Board of Management
Documentation supervisor: S. Reiser
Alfred Kärcher SE & Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Ph.: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2018/10/01
Order num-
Item No.,
ber, spare
unpacked
part
2.445-043.0 6.445-059.0
2.042-022.0 6.445-085.0
2.445-031.0 6.445-039.0
2.445-045.0 6.445-063.0
2.445-047.0 6.445-065.0
2.445-051.0 6.445-069.0
S. Reiser
Director Regulatory Affairs & Certification

Technical data

Electrical connection
Battery pack nominal voltage
Degree of protection
Protection class
Nominal power
Maximum power
Device performance data
Tank content
Fluid filling quantity
Air quantity (max.)
Vacuum (max.)
Operating time at full battery
charge - Battery Power 36/50 bat-
tery pack
Operating time at full battery
charge - Battery Power+ 36/60
battery pack
Operating time at full battery
charge - Battery Power+ 36/75
battery pack
Dimensions and weights
Typical operating weight
Length x width x height
Diameter of the suction hose
Length of the suction hose
Ambient conditions
Ambient temperature
Determined values in acc. with EN 60335-2-69
Sound pressure level L
Uncertainty K
pA
Hand-arm vibration value
Uncertainty K
Subject to technical modifications.
English
V
36 DC
IPX4
III
W
500
W
575
l
22
l
10
3
m
/h
122
kPa
14,6
(mbar)
(146)
Minutes 21
Minutes 24
Minutes 31
kg
8,8
mm
405 x
370 x
500
mm
35
m
1,9
°C
0/+40
dB(A)
70
pA
dB(A)
2
2
m/s
<2,5
2
m/s
0,2
13

Werbung

loading

Diese Anleitung auch für:

Nt 22/1 ap bp pack l