Herunterladen Inhalt Inhalt Diese Seite drucken

Installation; Operation - S&P COR-F-1000 N Handbuch

Vorschau ausblenden Andere Handbücher für COR-F-1000 N:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 19
ENGLISH
Except for the COR-F-1000 N RF, F-1500 N RF and F-2000 N RF, that can only be used as an Air Curtain with fresh air, the
rest of models on this range have the option of working either with fresh or warm air.
We advise you to check that the unit is in perfect condition when unpacking it, as any manufacturing or quality defect
is covered by the S&P guarantee.
IMPORTANT: SAFETY GUIDELINES
The appliance must not be right above or below a socket.
Do not cover the unit with clothes or objects that may obstruct the airfl ow and cause overheating.
While in operation, the connection cable must not be in front of the air outlet.
If it is installed in the bathroom, it must be placed so that the switches or other devices of command cannot be
touched for a person that be in the bathtub or shower.
There must not be any infl ammable objects at less than 50 cm from the unit (such as window curtains, etc.). Keep
the inlet and outlet grilles clean. When cleaning them, disconnect the unit from the main supply. Do not manipulate
the unit with wet hands.
The installation work must be carried out by an electrician.
IMPORTANT: THIS APPLIANCE MUST BE EARTHED.
The means of disconnection from the mains supply must have an opening distance of at least 3 mm in all poles.
To operate the unit as an Air Curtain, the maximum distance to the fl oor must not be greater than 3 m.
The minimum distance between the Air Curtain and the fl oor must be 1,8 m.

INSTALLATION

The unit must be fi xed to a convenient surface, and the minimum distances shown on Fig. 1 must be kept.
To install the unit, proceed as follows:
If the spiral nuts already placed in the device are used, there must be marked the centers of
the screws (M-8) according to the table of Fig.2 (a) and Fig.2 (b). If the hanging fi xation is used, the centers must be
marked according to the table of Fig.3 (a) and Fig.3 (b) and place the screws (D) and the set squares (E). Then hang the
device and to fi x on the lowest part with the screw (G).
When the included wall bracket kit is used Fig. 4 (2 pcs. for 1000 models and 3 pcs. for 1500/2000 models) set the
support (L) to the back part of the curtain with the screws provided (I). Fix the brackets (J) to the wall to match with
the brackets on the curtain (L). See dimensions Fig. 3 (a) and Fig 3 (b). Then hang the device and fi x on the lowest
part with the screw (K).
ELECTRICAL CONNECTION (Fig. 5)
The COR Air Curtains are installed appliances. When installing these air curtains, the standards and regulations in
force in your country must be followed strictly adhered to. Within the installation an electrical isolation switch must
be present, to enable the installer to cut all supply lines.
Connect the unit to the mains supply, checking that the voltage and frequency are the same as those indicated on
the electrical rating plate. Use the cables with the number of wires and sections as indicated on the wiring diagram
for every model.
The connection can be made either through the back or by the side of the units. In case of connection by the side,
the lid of the connections must be mounted through the cable before carrying the connections.
Fix the cable with the clamp provided and mount the front cover.
When mounted in series the power supply line must be the same for all the COR air curtains and maintain electrical
phase order.

OPERATION

Each air curtain incorporates a remote control (radiofrequency) included inside the packing.
REMOTE CONTROL SYNCHRONIZATION
When the air curtain receives power supply for the fi rst time, within next 30 seconds the internal receiver remains
in synchronization mode. In this period is required to synchronize the remote control pressing simultaneously 2 and
holding down this, press down button number 5 (fi gure 8 and 9). When the process is done correctly, LED num. 1
will do a sequence of fl ashes.
11

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis