AMBIENT AIR CURTAIN OPERATION (FIGURE 9)
Button Description
1
Stand by LED
2
Switching-on and/or speed increase
3
Off and/or speed decrease
4
Selected speed LED
Top LED: Low speed - Lowe LED: High speed
5
Automatic mode
Note: Change to high speed if an end of stroke door is connected (CR-MAGNET accessory)
6
LED of AUTO mode activated
AMBIENT/HOT AIR CURTAIN OPERATION (FIGURE 8)
Button Description
1
Stand by LED
2
Switching-on and/or speed increase
3
Off and/or speed decrease
4
Selected speed LED
Top LED: Low speed - Lower LED: Medium speed - Both LEDs: High speed
5
Automatic mode
Note: Change to high speed and high heat power if an end of stroke door is connected
(CR-MAGNET accessory)
6
AUTO mode activated LED
7
Heat power increase
Note: Verify that winter mode is activated. High heat power is only compatible with high speed fan
8
Heat power decrease
9
Heat power LED
Top LED: Low power - Lower LED: High power
10
Winter mode
Note: If winter mode is off, buttons 5 and 6 are disabled
11
Winter mode activated LED
ADDITIONAL COMMON FEATURES
Potentiometer RV66 (fi gure 7) adjusts the period of time, between 30 sec. and 10 min., that air curtain will remain
in maximum performance once door sensor detects that door is open and AUTO mode being activated. (Factory
setting: 30 seconds).
Potentiometer RV68 (fi gure 7) adjusts the period of time, between 30 sec. and 10 min., that internal fan will remain
working once heat power is stopped. (Factory setting: 30 seconds).
To access to these potentiometers check Figure 6.
PROTECTION AGAINST OVERHEATING
The COR Air Curtains are fi tted with one thermal fuse which automatically disconnects the unit in case of overheating.
In the event of this happening please contact the offi cial S&P dealer in your area.

MAINTENANCE

The COR Air Curtains do not need any special maintenance, but it is recommended to keep the inlet and outlet grilles
clean. Clean them with a dry cloth (avoid using solvents or abrasive
detergents). Once a year, the inside parts should be cleaned by a qualifi ed electrician using compressed air or a
vacuum cleaner. Disconnect the unit from the mains supply before carrying out this operation.
AFTER SALES SERVICE
In case of any problem with the unit, it is advised to contact your S&P dealer. Any manipulation of the appliance by
personnel not appointed by S&P will cancel the guarantee.
S&P reserves the right to modify the product without prior notice.