Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specification; Technical Data - Anest Iwata W-200 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für W-200:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 28
W-200
HIGH T.E.C. Series_ PRESSURE | SUCTION
ANEST IWATA spray guns, have been designed for the application of paints, lacquers and other products that can be atomized by means
of compressed air, on all surfaces suitable to receive this type of treatment.
1. IMPORTANT INFORMATIONS
IMPORTANT
ALWAYS OBSERVE WARNINGS AND CAUTIONS IN THIS MANUAL
SYMBOL
WARNING
WARNING
CAUTION
IMPORTANT

2. TECHNICAL SPECIFICATION

MODELS
Max. working air pressure:
Weight g (lbs):
Noise level (LAeqT)*:
Air Connection
Fluid Connection
Max. Temperature range:
* Measuring point: 1m backwards from gun, 1.6 m height.

2.1 TECHNICAL DATA

MODELS
W-200-084P
W-200-104P
W-200-124P
W-200-082P
W-200-102P
W-200-122P
W-200 WB-081P
W-200 WB-101P
W-200 WB
W-200 WB-121P
W-200-151ZP
W-200-201ZP
W-200 ZP
W-200-251ZP
W-200 S18
S18 | -S25
W-200 S25
W-200-152S
W-200-182S
W-200-202S
W-200-251S
W-200 WB-162S
W-200 WB
W-200 WB-182S
W-2003
W-2003
W-2003
This manual is an integral part of pressure spray gun and must to be read carefully before starting
ANY ACTIVITY involving the use, adjustment and maintenance of the equipment, including its handling.
This manual must be stored in a safe place for any future reference.
Be sure to observe warnings and cautions in this instruction manual.
If not, it can cause paint ejection and serious bodily injury by drawing organic solvent.
This ANEST IWATA pressure spray guns complies to ATEX regulations 2014/34/EU.
Protection level: II 2 G X Suitable for using Zones 1 and 2.
X marking: Any static electricity should be discharged from the spray gun and needs to be diverted to
the ground via a conductive air hose not included.
HAZARD LEVEL
POTENTIALLY
W-200
W-200 WB
380 (0.84)
380 (0.84)
81.2 dB(A)
76.8 dB(A)
G3/8"
G3/8"
NOZZLE
AIR CAP SET
ORIFICE
mm (in)
0.8 (0.031)
1.0 (0.039)
W-400 LV2
1.2 (0.047)
W-200
0.8 (0.031)
1.0 (0.039)
W-200 G2P
1.2 (0.047)
0.8 (0.031)
1.0 (0.039)
W-200 WB1
1.2 (0.047)
1.5 (0.059)
2.0 (0.079)
W-200 R1Z
2.5 (0.098)
W-200
1.0 (0.039)
W-200 G2P
1.5 (0.059)
W-200 K2
1.8 (0.071)
W-200
2.0 (0.079)
W-200 R2
2.5 (0.098)
W-200 W1
1.6 (0.063)
W-400 WB2
1.8 (0.071)
2.0 (0.079)
W-200 R1
2.5 (0.098)
W-200 W1
DEATH OR SERIOUS INJURY
HAZARDOUS
MINOR TO MODERATE INJURY
SITUATION
PROPERTY DAMAGE
W-200 ZP
W-200 S18
6.8 bar (98 PSI)
390 (0.86)
450 (0.99)
79 dB(A)
81.2 dB(A)
G1/4"
G3/8"
G1/4"M - NPSM 1/4"F
Atmosphere 5 ~ 40 °C / Air-Fluid 5 ~ 43 °C
AIR PRESSURE
MARK
at Gun Inlet
bar (PSI)
2.0 (29)
3.0 (43)
1.6 (23)
3.5 (50)
3.0 (43)
3.0 (43)
2.0 (29)
2.9 (42)
CONSEQUENCE
W-200 S25
450 (0.99)
81.2 dB(A)
G1/4"M - G1/4"M
FLUID
AIR
OUTPUT
CONSUMPTION
ml/min
l/min (cfm)
255
360 (12.7)
500
560 (19.8)
200
250
340 (12)
300
760
500 (17.7)
500
560 (19.8)
240
330 (11.7)
290
350
360 (12.7)
760
500 (17.7)
170
430 (15)
200
270 (9.53)
--
360 (12.7)
EN
W-2003
390 (0.86)
73.7 dB(A)
M16x1
PATTERN
WIDTH
mm (in)
280 (11.0)
400 (15.7)
360 (14.2)
380 (15.0)
370 (14.6)
360 (14.2)
290 (11.4)
340 (13.4)
290 (11.4)
370 (14.6)
315 (12.4)
330 (13.0)
300 ~ 400
3

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

W-200 wbW-200 zpW-200 s18W-200 s25W-2003

Inhaltsverzeichnis