Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Safety Warning - Anest Iwata WS-400 BASE Serie Bedienungsanleitung

Fliessbecher pistolen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 35
WS-400 Series2 [BASE & CLEAR] - LS-400 Series2 GRAVITY SPRAY GUNS
EN

6. TECHNICAL DATA

Nozzle
Air cap set
Orifice
Mark
MODEL
(mm)
WS-400 BASE
WS-400-OBS.0
OBS-0
WS-400-OBS
OBS
WS-400-02-OBS
WS-400-OBS.1
OBS+1
WS-400-BFS
BF-S
WS-400-03-BF
WS-400 CLEAR
WS-400-12H03
12 HD
WS-400-13H03
13 HD
WS-400-03
WS-400-14H03
14 HD
WS-400-15H03
15 HD
LS-400 ET
LS-400-1206
12 ET
LS-400-1306
13 ET
LS-400-06
LS-400-1406
14 ET
LS-400-1506
15 ET
LS-400 ETS
LS-400-12S06
12 ETS
LS-400-13S06
13 ETS
LS-400-06
LS-400-14S06
14 ETS
LS-400-15S06
15 ETS
*Atomizing air pressure means air pressure at spray gun inlet when trigger is pulled and air flows
**Spray distance at 150mm
7. CHECKING OF THE PRODUCT
WHEN RECEIVING THE SPRAY GUN, MAKE SURE THAT IT HAS NOT BEEN DAMAGED DURING TRANSPORT
OR STORAGE AND ALSO CHECK THAT ALL THE FOLLOWING CONTENTS ARE INSIDE THE BOX.
STANDARD SPRAY GUN_Set includes:
Allen wrench
Brush
Universal spanner
Twisted brush
Ø10 mm
Instruction manual
4
Atomizing
Air pressure
Air
Fluid
air pressure*
inside air cap
Consumption
output
bar (PSI/Mpa)
bar (PSI/Mpa)
l/min (cfm)
ml/min
210
215
2.0
370
-
(29 / 0.20)
(13.1)
235
245
220
245
2.0
370
-
(29 / 0.20)
(13.1)
260
280
165
175
1.8
0.7
400
(26 / 0.18)
(10 / 0.07)
(14.1)
185
190
160
170
1.8
0.7
420
(26 / 0.18)
(10 / 0.07)
(14.8)
185
195
DIGITAL VERSION with Digital Pressure Gauge DPG-1_Set includes:
Allen wrench
Screwdriver
Brush
Coin battery 3 volt
Universal spanner
Twisted brush
Trigger Locking
Ø10 mm
Clip & Pin Cap
IMPORTANT: In order to proceed in the
Instruction manual
correct way with the installation or the
replacement of the battery it is important to
strictly follow the instructions as showed on
SECTION 13.
WS-400 Series2 [BASE & CLEAR] - LS-400 Series2 GRAVITY SPRAY GUNS

8. SAFETY WARNING

Pattern
WARNING
FIRE AND EXPLOSION HAZARDS
width**
SPARKS AND OPEN FLAMES ARE STRICTLY PROHIBITED
mm (in)
Paints can be highly flammable and can cause fire.
Do not expose to open flames, electrical goods, cigarettes etc.
255 (10.0)
SECURELY GROUND SPRAY GUN BY USING A CONDUCTIVE AIR HOSE. ELECTRICAL
255 (10.0)
RESISTENCE: <1MΩ. - ALWAYS ensure that the spray gun is earthed correctly.
260 (10.2)
Insufficient grounding can cause fire and explosion due to static electric sparking.
250 (9.8)
NEVER USE THE FOLLOWING HALOGENATED HYDROCARBON SOLVENTS which can cause
cracks or dissolution on gun body (aluminium) by chemical reaction. UNSUITABLE SOLVENTS:
methyl chloride, dichloromethane, 1.2-dichloroethane, carbon tetrachloride, trichloroethylene,
245 (9.6)
1.1.1-trichloroethane. BE SURE THAT ALL FLUIDS AND SOLVENTS ARE COMPATIBLE WITH
250 (9.8)
GUN PARTS.
255 (10.0)
260 (10.2)
WARNING
PROTECTION OF HUMAN BODY
USE IN A WELL-VENTILATED SITE BY USING A SPRAY BOOTH.
230 (9.1)
If not, poor ventilation can cause organic solvent poisoning and catch fire. If you feel any abnormality
235 (9.3)
during operation, consult a medical doctor immediately.
240 (9.4)
ALWAYS WEAR PROTECTIVE GEAR (safety glasses, mask, gloves.)
245 (9.6)
If not, cleaning liquid, etc., can cause inflammation of eyes and skin.
In case of any physical discomfort for skin or eyes, immediately seek a medical advice.
200 (7.9)
The noise level of ANEST IWATA Spray Gun doesn't exceed the 85 dB (A) A-weighted sound
205 (8.1)
pressure value about the risk of daily exposure to noise. THE USE OF INDIVIDUAL HEARING
210 (8.3)
PROTECTION IS ALWAYS RECOMMENDED, because the terms of use and the influence of other
noises in the job area, could increase the average value allowed.
215 (8.5)
Pulling trigger many times during operation, may cause carpal tunnel syndrome.
ALWAYS REST, IN CASE OF TIREDNESS.
WARNING
IMPROPER USE OF THE EQUIPMENT
NEVER EXCEED MAXIMUM OPERATING PRESSURE AND MAXIMUM OPERATING TEMPERATURE.
Use at more than max. operating pressure can cause explosion of Spray Gun resulting in great danger.
ALWAYS RELEASE AIR AND FLUID PRESSURE BEFORE CLEANING, DISASSEMBLING OR
SERVICING. Otherwise, remaining pressure can cause bodily injury due to improper operation or
scattering cleaning liquid.
NEVER POINT SPRAY GUN TOWARDS PEOPLE OR ANIMALS.
TIP OF FLUID NEEDLE SET HAS A SHARP POINT.
Do not touch the tip during maintenance to avoid accidents.
NEVER USE THIS GUN TO SPRAY FOODS, CHEMICALS, CORROSIVE AND/OR ABRASIVE
PRODUCTS, otherwise the blend of foreign substances could cause corrosion of the fluid pas-
sages, which could adversely affect health.
ALWAYS DISASSEMBLE DIGITAL PRESSURE GAUGE MODULE FROM SPRAY GUN HANDLE
BEFORE CLEANING OR SERVICING.
NEVER ALTER THIS SPRAY GUN OR THE DIGITAL PRESSURE GAUGE MODULE DPG-1.
If done, it can cause insufficient performance and failure or in extreme cases, explosions.
WARNING
OTHER PRECAUTIONS
IF SOMETHING GOES WRONG, IMMEDIATELY STOP OPERATION AND FIND THE CAUSE
OF FAILURE. Do not use again until you have solved the problem.
NEVER DISASSEMBLE, MODIFY OR ATTEMPT TO REPAIR THE DIGITAL PRESSURE MODULE
DPG-1. In case of failure or malfunction, contact exclusively your ANEST IWATA Customer
Technical Service.
EN
5

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis