Changing the calibration of the temperature detection probe
If the location of the device does not permit suitable detection of the temperature, it is possible to change the
temperature detected by ±3 °C with increases of a tenth of a degree.
Enable / disable automatic advance
This function enables the device to automatically adapt the system start-up time in order to have the desired
temperature at the time set.
The advance is calculated according to the difference between the temperature detected and the one set. It
is possible to have an advance of up to a maximum of three hours prior to the time that has been set for the
temperature to be reached.
Example of operation
If the device is programmed to have a temperature of 20 °C at 7.00 a.m. and the automatic advance is not
active, at 7.00 a.m. the system will come on, without however guaranteeing 20 °C at 7.00 a.m.
If automatic advance is on the programmable thermostat will bring forward switching on the system so as
to try to reach 20 °C at 7.00 a.m.; thanks to the auto-recognition mechanism, the programmable thermostat
stores the thermal parameters of the room in order to be more accurate in subsequent days in terms of attaining
the thermal objective set.
Use the
detected by the desired value and press the
button to move on to the next parameter
to be configured.
A
Use the
deactivate (OFF) the automatic advance and
press the
button to move on to the next
parameter to be configured.
A
arrows to change the data
arrows to activate (ON) or