With a blower device
Check adequate air flow (see Instructions for Use of the blower unit).
With a compressed-airline device
Check before use that air passes through the hose into the mask.
4.1 Fitting of the filter
Sari + Pro2000: Remove eventual safety plugs from the filter. Screw the filter tightly in the
connector of the mask (=inh. valve body).
Sari + Pro2000 + blower device: Screw the filters to the blower device and fix the breathing hose
to the connector of the mask.
4.2 When needed, connect the spectacles to the inner mask and adjust their position.
4.3 A sweat band is recommended to control excessive hair.
4.4 Loosen the head harness straps.
4.5 Locate the chin pocket of the mask properly on the chin and pull the head harness over the
head.
4.6 Check that the chin is in the chin pocket. Tighten the straps (in the order 1–2–3). Start with neck
straps, pull backwards (not outwards). Then adjust the temple straps and finally the upper strap. The
cradle/net lies centered on the back of the head.
Note! Check that the faceseal touches the skin all around, especially under the chin pocket. Try
moving the mask sideways to verify that there is no slippage.
4.7 Check tightness of the mask (two alternative methods):
1) Cover the exhalation opening of the mask with your hand. Exhale gently to create overpressure.
There must be no leakage between the face and the faceseal.
2) Cover the filter opening with your hand. Inhale to make the mask press onto your face.
If you fail to get a tight fit (=potential leakage), adjust the head harness and filter.
5. Maintenance and storage
Inspect the product regularly for damage and replace where necessary.
5.1 Test for function and leak-tightness
If components have been replaced (visor, valve discs or speech diaphragm), a test for function and
leak-tightness must be carried out with an appropriate test device (e.g. Pro-Tester code 5141080).
The test is also done in case of a mask stored unused for a longer period.
Check also that the faceblank has maintained its shape, the head harness is reasonably elastic, the
visor and the faceseal are undamaged, and that the valve discs and the speech diaphragm's O-ring
are good and well in position. Damage must be repaired.
5.2 Replacing the visor
The visor is available in polyamide, polycarbonate, chemical-resistant laminated glass or
polycarbonate with a chemical-resistant and scratch-proof coating. The material code is found at the
upper right-hand corner of the visor. Replace visor if damaged, dirty or scratched.
Material code:
F
polycarbonate (PC)
F
hard coated polycarbonate (HC)
polyamide (PA)
triplex
011707