Herunterladen Inhalt Inhalt Diese Seite drucken

Allgemeine Ersatzteilliste / General Spare Parts List; Angaben Gemäß Erp-Durchführungsverordnung 327/2011 | Indications According To Erp Implemen; Machine Specifications - Elektror ND series Betriebs- Und Montageanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operating and assembly instructions ND
CONTENT
EN
1
MACHINE SPECIFICATIONS ...................................10
2
STORAGE OF THE MACHINE .................................12
3
MACHINE ..................................................................12
4
5
INSTRUCTIONS FOR MAINTENANCE ...................15
6
OF OPERATION AND REMOVAL ............................16
7
8
PURSUANT TO ANNEX II 1 B DECLARATION OF
CONFORMITY IN ACC. WITH EVPG (ENERGY
CONSUMPTION RELEVANT PRODUCTS ACT)
SECTION 4 PARAGRAPH 1 .....................................17
9
DRAWING ................................................................18
10
ALLGEMEINE ERSATZTEILLISTE / GENERAL
SPARE PARTS LIST ................................................19
11
SPECIFICATIONS ....................................................20
12
ting regulation 327/2011 .........................................24
These Operating and Assembly Instructions should be avail-
able to operating personnel at all times. Read these Operat-
ing and Assembly Instructions carefully before installing and
putting the blower into service.
Subject to change without prior notice. If in any doubt, the
manufacturer should be consulted. This document is protect-
ed by copyright. It must not be disclosed to third parties with-
out our express written consent. Any form of duplication or
recording and storage in electronic equipment is forbidden.

1 MACHINE SPECIFICATIONS

10
Please refer to the cover sheet for our address.
For details of the scope of these Operating and Assembly
Instructions, please refer to the Declaration of Installation
Conformity pursuant to Annex II 1 B.
The technical specifi cations on page 20 apply to the
standard version. Your blower's specifi cations may diff er
from these specifi cations (refer to rating plate). If this is the
case, please refer to the enclosed, additionally applicable
documents or your own applicable Operating and Assembly
Instructions.
Rating plate
The data on the rating plate is applicable to connection,
maintenance and ordering of spare parts. Also refer to the
rating plate for the serial number of the appliance and its year
of manufacture.
Typ
Mot. EN 60034-1
kW cos
Hz
D-73760 Ostfildern
Germany
Nr.
IP
W-Kl.F
kW cos
min
min
Hz
-1
-1
V
A
A
1.1 Designated use
The blowers are exclusively designed for conveying gaseous
media without solids.
Any solid matter or impurities in the medium to be conveyed
must be fi ltered out before they enter the blower. We recom-
mend a condensed water borehole at the lowest point in the
housing in the event of the formation of condensation.
Use of the blowers for
• aggressive,
• abrasive,
• sticky,
• toxic,
• potentially explosive or
• very moist
media is not permissible.
The maximum temperature of the conveyed medium must
not exceed -20°C to +80°C in the standard version and
180°C in special versions fi tted with a thermal barrier. Solid
particles or contaminants must be removed by a fi lter unit
before entering the blower.
The blower is not suitable for installation outdoors without
special measures. The blower is fundamentally designed for
S1 operation (continuous operation). However, a maximum
of 30 switching operations per hour are permitted.
The standard version of the blower is not suitable for use in
explosive atmospheres.
Special versions for applications not mentioned above are
available on request. Remodelling and modifi cation of the
blower are not permitted. In the case of special equipment,
the enclosed supplementary Operating and Assembly In-
structions must be observed and adhered to. The supple-
mentary instructions diff er in certain respects from these Op-
erating and Assembly Instructions.
Elektror blowers off er a high level of operational reliability.
As the blowers are high-powered machines, the safety in-
structions must be strictly observed in order to avoid injuries,
damage to objects and to the machine itself.
1.2 Mechanical hazards
The mechanical hazards in Elektror blowers have been mini-
mised in accordance with the current state of the art, as well
as the requirements for safety and health protection. To elimi-
nate any further risk on the part of the operator, we recom-
mend that suitable protective gear be used and worn during
all lifecycle phases of the appliance (please refer to the in-
structions below).
Warning!
Risk of injury from shearing/entanglement
In special versions with temperature lock (1), the-
re is a risk of limbs being sheared and clothing/
hair becoming entangled.
Wear personal protective equipment, close-fi tting
clothing, and a hair net during all phases of the
device's life.