Prior to set up
Floor bearing capacity
Ensure that the substructure is capable of bearing the weight of the
stove prior to set-up.
Note
No modifications may be made to the firing installation. This also
leads to loss of warranty and guarantee.
Floor protection
A base is recommended (glass, sheet steel or ceramic) if the floor is
combustible (wood, carpet, etc.). Please observe the respective local
regulations and rules.
Flue pipe connection
Flue pipes pose a particular source of hazard regarding gas leaks
Q
and fire. Get the advice of an authorised specialist company for
the layout and assembly.
Please observe the corresponding installation guidelines for walls
Q
panelled with wood when connecting your flue pipes to the stove.
Observe the formation of flue gas (atmospheric inversion) and
Q
draughts when the weather is unfavourable.
Infeed of too little combustion air can lead to smoke in the rooms
Q
or to flue gas leaks. Hazardous deposits in the stove and chimney
may also occur.
If flue gas escapes, let the fire burn out and check whether all the
Q
air inlet openings are free and the flue gas pipes and the stove
pipe are clean. If in doubt notify the master chimney sweep since
draught malfunctions may be connected to your chimney.
The correct chimney connection
There are several ways to connect your stove to the chimney, eg:
1) wind break, 2) chimney, 3) inspection opening
For the selection of the connection and to ensure a proper connection
between the stove and chimney, please read the guide „INSTALLING
THE STOVE" or ask your local chimney sweep.
Stoves type 1 (BA 1):
Suitable for multiple occupancy. (Note the different country
Q
regulations.)
These may only be operated with the combustion chamber door
Q
closed.
The combustion chamber door is to be kept closed when the
Q
stove is not in operation.
Fouling of the chimney i.e. deposits of highly inflammable materials
Q
such as soot and tar and subsequently fire in the chimney may
occur if the chimney is miscalculated and dimensioned wrong.
If this occurs, disconnect the mains plug. Phone the fire brigade
Q
and get yourself and other residents out of harm's way.
Note
Your pellet stove has been tested as a room-air independent stove
according to EN14785. It can be operated room air dependent or
room air independent.
ROOM-AIR INDEPENDENT OPERATION:
The stove is certificated for type FC52x / FC62x of the approval
principles for the inspection and evaluation of ambient air
independent fireplaces specified by the Deutsches Institut für
Bautechnik (DIBT) (German Institute for Building Technology).
Thanks to an air-tight configuration of the air supply line and flue
pipes the stove may be operated in air-tight rooms and in rooms
with room-air installations (e.g. controlled ventilation and venting
systems, extractors etc.).
ROOM-AIR DEPENDENT OPERATION:
In combination with room-air installations (e.g. controlled
ventilation and venting systems (extractors etc.) it must
be ensured that the stove and the room air system are
monitored and safeguarded mutually (e.g. via a differential
pressure controller). The combustion air infeed of approx.
20 m
/h must be ensured.
3
Please observe the respective local regulations and rules in
consultation with your master chimney sweep. For changes after
the printing of this manual, we can not assume any liability. We
reserve the right to change without notice.