  • DEUTSCH, seite 43
PRELIMINARY CHECKINGS
Before installing WISANT, please check the following basic points:
• The door must be suitable to be automated (check the door
operation manual and directions). The door structure itself
must be stout and appropriate to be automated.
• Fix the engine steadily and using suitable material.
• If necessary, make the structural calculation and enclose to
the technical specification paper.
WISANT actuator
Flashing light with built-in antenna
Key switch
Photocells
Transmitter
Digital radio switch
Control unit
• The door must be functional and safe.
• The door must open and close easily without any friction.
• The door must be equipped with balance springs, otherwise
• It is recommended to install limit devices on door tracks to

INSTALLATION LAYOUT

cable 4 x 1,5 mm
2
cable 2 x 0.5 mm
2
cable RG-58
cable 3 x 0.5 mm
2
cable 4 x 0,5 mm
2
(RX)
cable 2 x 0,5 mm
2
(TX)
cable 3 x 1 mm
2
11
the operator will be damaged. Before installation of the door
operator, the door should be carefully checked for being kept
well balance.
prevent the door from sliding out of the tracks.